Претраживање
Приказ резултата 31-40 од 40
Application of Nanocrystalline Pseudobrookite (Fe2TiO5) Thick Films for Humidity Sensing
(IEEE Computer Society, 2018)
Pseudobrookite nanocrystalline thick films were screen printed on alumina substrate with small interdigitated PdAg electrodes (width 6 mm, length 12 mm, electrode spacing 0.2 mm) and fired at 600°C for 30 minutes. Scanning ...
Accuracy improvements of consumer-grade 3D sensors for robotic applications
(IEEE, 2013)
Recent advances in development of low-cost 3D sensors, such as Microsoft Kinect, bring attractive opportunities to robot system integrators. The accuracy provided by such sensors is generally unsatisfactory for many robotic ...
Nanocomposite Zn2SnO4/SnO2 Thick films as a Humidity Sensing Material
(IEEE, 2019)
Nanocomposite Zn2SnO4/SnO2 powder was obtained by solid state synthesis from homogenized starting nanopowders of ZnO and SnO2 mixed in the 1:1 molar ratio, structurally and morphologically characterized using X-ray diffraction ...
Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures
(Institute of Electrical and Electronics Engineers (IEEE), 2019)
Real-time in situ operation of bio/chemical sensors assumes detection of chemical substances or biological specimens in samples of complex composition. Since sensor selectivity cannot be ideal, adsorption of particles other ...
Adsorption–desorption noise in nanowire FET biosensors
(IEEE, 2012)
The adsorption-desorption (AD) noise in nanowire FET biosensors is analyzed, which manifests itself in the form of gate voltage fluctuations resulting from the fluctuations of the number of adsorbed particles. The derived ...
RF MEMS and NEMS components and adsorption-desorption induced phase noise
(IEEE, 2014)
Radio frequency micro- and nanoelectro-mechanical systems (RF MEMS and RF NEMS) and technologies have a great potential to overcome the constraints of conventional IC technologies in realization of fully integrated ...
Alkali-Aggregate Reactions in Concrete
(Atlantis Press, 2016)
In most concretes, aggregates are more or less chemically inert. However, some aggregates react with the alkali hydroxides in concrete, causing expansion and cracking over a period of many years. This alkali-aggregate ...
Highly sensitive graphene-based chemical and biological sensors with selectivity achievable through low-frequency noise measurement — Theoretical considerations
(IEEE, 2014)
We have developed a theory of the low-frequency noise caused by interaction of the analyte with the active area of chemical and biological sensors. The main result is an analytical expression for the spectral density of ...
Optimization and Application of NTC Thick Film Segmented Thermistors
(Zurich : Trans Tech Publications Inc., 2013)
NTC thermistor paste for printing thermal sensors on alumina was formed of very fine Ni0.5Cu0.2Zn1.0Mn1.3O4 thermistor powder obtained by a combined mechanical activation/thermal treatment process, organic vehicle and glass ...
Nanostructured (Y1-xGdx)2O 3:Eu3+ powders obtained through aerosol synthesis
(Hoboken, NJ : John Wiley & Sons, 2010)
In this study, nanophase, spherical, polycrystalline (Y 1-xGdx)2O3:Eu3+phosphor particles were synthesized from aerosols of corresponding nitrate solutions, ultrasonically generated at 1.3 MHz frequency, and thermally ...