Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems
2011
Аутори
Knežević Jugović, ZoricaJugović, Branimir
Jakovetić, Sonja
Bezbradica, Dejan
Antov, Mirjana
Saied, Omar Ali
Gvozdenović, Milica M.
Остала ауторства
Markoš, JozefКонференцијски прилог (Објављена верзија)
Метаподаци
Приказ свих података о документуАпстракт
The present study compares the results of two different methods employed for preparation of polyaniline based glucose biosensor with respect to enzyme loading, biosensing efficiency and potential stability. Kinetic analysis of the potentiometric data for two enzyme immobilized electrode systems show that the GOx/PANI electrode is suitable for assaying samples with low analyte concentrations, whereas the GOx/m-ABA/PANI electrode system exhibits a better potential stability. It may therefore be possible to achieve high level of biosensing efficiency by chemical modeling and synthesis combined with careful selection of the immobilization method.
Кључне речи:
polyaniline-based biosensor / polyaniline film / m-aminobenzoate acid / enzyme cross-linking / covalent immobilizationИзвор:
Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering, 2011, 1519-1525Издавач:
- Tatranské Matliare : Slovak Society of Chemical Engineering
Финансирање / пројекти:
- Модификација металних и неметалних материјала електропроводним полимерима за примену у новим технологијама (RS-MESTD-MPN2006-2010-142044)
Институција/група
Институт техничких наука САНУ / Institute of Technical Sciences of SASATY - CONF AU - Knežević Jugović, Zorica AU - Jugović, Branimir AU - Jakovetić, Sonja AU - Bezbradica, Dejan AU - Antov, Mirjana AU - Saied, Omar Ali AU - Gvozdenović, Milica M. PY - 2011 UR - https://dais.sanu.ac.rs/123456789/549 AB - The present study compares the results of two different methods employed for preparation of polyaniline based glucose biosensor with respect to enzyme loading, biosensing efficiency and potential stability. Kinetic analysis of the potentiometric data for two enzyme immobilized electrode systems show that the GOx/PANI electrode is suitable for assaying samples with low analyte concentrations, whereas the GOx/m-ABA/PANI electrode system exhibits a better potential stability. It may therefore be possible to achieve high level of biosensing efficiency by chemical modeling and synthesis combined with careful selection of the immobilization method. PB - Tatranské Matliare : Slovak Society of Chemical Engineering C3 - Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering T1 - Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems SP - 1519 EP - 1525 UR - https://hdl.handle.net/21.15107/rcub_dais_549 ER -
@conference{ author = "Knežević Jugović, Zorica and Jugović, Branimir and Jakovetić, Sonja and Bezbradica, Dejan and Antov, Mirjana and Saied, Omar Ali and Gvozdenović, Milica M.", year = "2011", abstract = "The present study compares the results of two different methods employed for preparation of polyaniline based glucose biosensor with respect to enzyme loading, biosensing efficiency and potential stability. Kinetic analysis of the potentiometric data for two enzyme immobilized electrode systems show that the GOx/PANI electrode is suitable for assaying samples with low analyte concentrations, whereas the GOx/m-ABA/PANI electrode system exhibits a better potential stability. It may therefore be possible to achieve high level of biosensing efficiency by chemical modeling and synthesis combined with careful selection of the immobilization method.", publisher = "Tatranské Matliare : Slovak Society of Chemical Engineering", journal = "Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering", title = "Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems", pages = "1519-1525", url = "https://hdl.handle.net/21.15107/rcub_dais_549" }
Knežević Jugović, Z., Jugović, B., Jakovetić, S., Bezbradica, D., Antov, M., Saied, O. A.,& Gvozdenović, M. M.. (2011). Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems. in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering Tatranské Matliare : Slovak Society of Chemical Engineering., 1519-1525. https://hdl.handle.net/21.15107/rcub_dais_549
Knežević Jugović Z, Jugović B, Jakovetić S, Bezbradica D, Antov M, Saied OA, Gvozdenović MM. Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems. in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering. 2011;:1519-1525. https://hdl.handle.net/21.15107/rcub_dais_549 .
Knežević Jugović, Zorica, Jugović, Branimir, Jakovetić, Sonja, Bezbradica, Dejan, Antov, Mirjana, Saied, Omar Ali, Gvozdenović, Milica M., "Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems" in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering (2011):1519-1525, https://hdl.handle.net/21.15107/rcub_dais_549 .