Приказ основних података о документу

dc.creatorĐinović, Zoran
dc.creatorTomić, Miloš
dc.creatorPavelka, R.
dc.creatorSprinzl, G.
dc.creatorTraxler, H.
dc.date.accessioned2020-12-20T16:49:31Z
dc.date.available2020-12-20T16:49:31Z
dc.date.issued2020
dc.identifier.issn1847-3946
dc.identifier.urihttps://dais.sanu.ac.rs/123456789/9985
dc.description.abstractIn this paper we present the results obtained by contactless measurement of vibration of the incus inside the middle ear of a human cadaver, exposed to an external calibrated sound source. The measurement configuration was a Michelson fiber-optic interferometer based on a 3x3 fiber optic coupler, with a VCSEL source. The interferometric signal fading was solved using two quasiquadrature signals and specialized signal processing. The ossicle reflection was augmented by a very light piece of retroreflective material attached to the bone. We measured the amplitude of vibration at different sound pressure levels, independently monitored by a decibel meter placed in the proximity of the cadaver ear. The accuracy of the measurement technique was proved by using a calibrated piezo transducer exposed to vibrate with amplitude of 7nm at 1kHz. We performed the experiments on 8 cadavers in total. The measured amplitudes were found to be in the range between 1 pm and 1 nm, under the sound excitation of 40-90 dB SPL @ 1kHz, respectively.
dc.language.isoensr
dc.publisherRijeka : Croatian Society for Information, Communication and Electronic Technology - MIPROsr
dc.relationNFB Austria & ACMIT Gmbh, Totally implantable fiber-optic sensing system for cochlear- and middle-ear hearing aids, Life Sciences grant: LS14-026sr
dc.rightsopenAccesssr
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceProceedings / MIPRO 2020 : 43rd International Convention, September 28, 2020 - October 2, 2020, Opatija, Croatiasr
dc.subjectfiber-optic sensorssr
dc.subjectvibration measurementsr
dc.subjectimplantable microphonesr
dc.subjecthearing aidsr
dc.titleMeasurement of the human cadaver ossicle vibration amplitude by fiber-optic interferometryen
dc.typeconferenceObjectsr
dc.rights.licenseBY-NC-NDsr
dcterms.abstractЂиновић, Зоран; Томић, Милош; Павелка, Р.; Спринзл, Г.; Траxлер, Х.;
dc.citation.spage2232
dc.citation.epage2236
dc.type.versionpublishedVersionsr
dc.identifier.fulltexthttps://dais.sanu.ac.rs/bitstream/id/41198/bitstream_41198.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_dais_9985


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу