Digitalni arhiv izdanja SANU
    • English
    • Српски
    • Српски (Serbia)
  • Srpski (latinica) 
    • Engleski
    • Srpski (ćirilica)
    • Srpski (latinica)
  • Prijava
Pregled rada 
  •   DAIS
  • Институт техничких наука САНУ / Institute of Technical Sciences SASA
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
  • Pregled rada
  •   DAIS
  • Институт техничких наука САНУ / Institute of Technical Sciences SASA
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
  • Pregled rada
JavaScript is disabled for your browser. Some features of this site may not work without it.

Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer

Samo za registrovane korisnike
2017
Autori
Jokić, Ivana
Đurić, Zoran G.
Radulović, Katarina
Frantlović, Miloš
Konferencijski prilog (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
An approximate model for efficient analysis of stochastic time response of microfluidic biosensors is presented, that considers a random AD process coupled with mass transfer (convection and diffusion) of target substance particles. The deterministic model of sensor response is also reviewed. We perform the analysis of the mass transfer influence on the kinetics and the steady-state value of the response calculated according to the two models (deterministic and stochastic). The results are presented for the sensors with different micro/nanoscale active surfaces. The comparison of the responses obtained by using the two models can be utilized to distinguish the cases in which the application of the deterministic model is justified from those in which the stochastic model is necessary. The presented findings enable more accurate interpretation of measurement results obtained by using micro/nanobiosensors.
Ključne reči:
adsorption / biological system modeling / biological techniques / bioMEMS / biosensors / fluidic reaction chamber / mass transfer / mathematical modelling / microbiosensors / microfluidic biosensors / microfluidics / microscale active surfaces / microsensors / nanobiosensors / nanobiotechnology / nanoscale active surfaces / nanosensors / patient diagnosis / random adsorption-desorption process / sensor response / steady-state value / stochastic model / stochastic processes / stochastic time response / target substance particles / time factors
Izvor:
2017 IEEE 30th International Conference on Microelectronics (MIEL), 2017, 127-130
Izdavač:
  • IEEE
Projekti:
  • Mikro, nano-sistemi i senzori za primenu u elektroprivredi, procesnoj industriji i zaštiti životne sredine (RS-32008)
  • Serbian Academy of Sciences and Arts, Project F-150

DOI: 10.1109/MIEL.2017.8190084

ISBN: 978-1-5386-2563-7

ISSN: 2159-1679

Scopus: 2-s2.0-85043596742
[ Google Scholar ]
1
URI
http://dais.sanu.ac.rs/123456789/3684
Kolekcije
  • Општа колекција / General collection
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
Institucija
Институт техничких наука САНУ / Institute of Technical Sciences SASA

DSpace software copyright © 2002-2015  DuraSpace
O Digitalnom arhivu izdanja SANU (DAIS) | Pošaljite zapažanja

re3dataOpenAIRERCUB
 

 

Kompletan repozitorijumInstitucijeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O Digitalnom arhivu izdanja SANU (DAIS) | Pošaljite zapažanja

re3dataOpenAIRERCUB