Determination of clindamycin in pig plasma after implantation of poly(D,Llactide-co-glycolide)/hydroxyapatite/clindamycin core–shell nanosphere by liquid chromatography-tandem mass spectrometry

Thumbnail
2010
Vukovic_9KMI_2010_IV-8.pdf (1.348Mb)
Authors
Vuković, Gorica
Lazić, Sanja
Šunjka, Dragana
Bursić, Vojislava
Šarčev, Ivan
Vukomanović, Marija
Ignjatović, Nenad
Uskoković, Dragan
Conference object (Published version)
Metadata
Show full item record
Abstract
Clindamycin was determined in pig plasma by liquid chromatography/tandem mass spectrometry (LC-MS/MS). The multiple reaction monitoring (MRM) mode of precursor-product ion transitions for clindamycin (m/z=421.1/126.1) and the internal standard, caffeine (m/z=192/125) was used. The samples were prepared by two methods: 0.1% formic acid in methanol and 1.5% trichloacetic acid. The recovery for the two preparation methods at 0.05mg/ml (n=6) was found to be for the first 104.3% and for the second method 106.5%, with repeatability RSD 1.1% and RSD 4.34%, respectively. The results of the comparison of the two different preparation methods of samples demonstrated that both methods were satisfactory.
Keywords:
LC-MS/MS / clindamycin / poly(D,L-lactide-co-glycolide) / hydroxyapatite / core-shell nanoparticles
Source:
Program and the Book of Abstracts / Ninth Young Researchers Conference Materials Sciences and Engineering, December 20–22, 2010, Belgrade, Serbia, 2010, 19-19
Publisher:
  • Belgrade : Institute of Technical Sciences of SASA
Projects:
  • Sinteza funkcionalnih materijala sa kontrolisanom strukturom na molekularnom i nano nivou (RS-142006)

ISBN: 9788680321264

[ Google Scholar ]
URI
http://dais.sanu.ac.rs/123456789/3453
Collections
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
Institution
Институт техничких наука САНУ / Institute of Technical Sciences of SASA
TY  - CONF
AU  - Vuković, Gorica
AU  - Lazić, Sanja
AU  - Šunjka, Dragana
AU  - Bursić, Vojislava
AU  - Šarčev, Ivan
AU  - Vukomanović, Marija
AU  - Ignjatović, Nenad
AU  - Uskoković, Dragan
PY  - 2010
UR  - http://dais.sanu.ac.rs/123456789/3453
AB  - Clindamycin was determined in pig plasma by liquid chromatography/tandem mass spectrometry (LC-MS/MS). The multiple reaction monitoring (MRM) mode of precursor-product ion transitions for clindamycin (m/z=421.1/126.1) and the internal standard, caffeine (m/z=192/125) was used. The samples were prepared by two methods: 0.1% formic acid in methanol and 1.5% trichloacetic acid. The recovery for the two preparation methods at 0.05mg/ml (n=6) was found to be for the first 104.3% and for the second method 106.5%, with repeatability RSD 1.1% and RSD 4.34%, respectively. The results of the comparison of the two different preparation methods of samples demonstrated that both methods were satisfactory.
PB  - Belgrade : Institute of Technical Sciences of SASA
C3  - Program and the Book of Abstracts / Ninth Young Researchers Conference Materials Sciences and Engineering, December 20–22, 2010, Belgrade, Serbia
T1  - Determination of clindamycin in pig plasma after implantation of poly(D,Llactide-co-glycolide)/hydroxyapatite/clindamycin core–shell nanosphere by liquid chromatography-tandem mass spectrometry
SP  - 19
EP  - 19
ER  - 
@conference{
author = "Vuković, Gorica and Lazić, Sanja and Šunjka, Dragana and Bursić, Vojislava and Šarčev, Ivan and Vukomanović, Marija and Ignjatović, Nenad and Uskoković, Dragan",
year = "2010",
url = "http://dais.sanu.ac.rs/123456789/3453",
abstract = "Clindamycin was determined in pig plasma by liquid chromatography/tandem mass spectrometry (LC-MS/MS). The multiple reaction monitoring (MRM) mode of precursor-product ion transitions for clindamycin (m/z=421.1/126.1) and the internal standard, caffeine (m/z=192/125) was used. The samples were prepared by two methods: 0.1% formic acid in methanol and 1.5% trichloacetic acid. The recovery for the two preparation methods at 0.05mg/ml (n=6) was found to be for the first 104.3% and for the second method 106.5%, with repeatability RSD 1.1% and RSD 4.34%, respectively. The results of the comparison of the two different preparation methods of samples demonstrated that both methods were satisfactory.",
publisher = "Belgrade : Institute of Technical Sciences of SASA",
journal = "Program and the Book of Abstracts / Ninth Young Researchers Conference Materials Sciences and Engineering, December 20–22, 2010, Belgrade, Serbia",
title = "Determination of clindamycin in pig plasma after implantation of poly(D,Llactide-co-glycolide)/hydroxyapatite/clindamycin core–shell nanosphere by liquid chromatography-tandem mass spectrometry",
pages = "19-19"
}
Vuković G, Lazić S, Šunjka D, Bursić V, Šarčev I, Vukomanović M, Ignjatović N, Uskoković D. Determination of clindamycin in pig plasma after implantation of poly(D,Llactide-co-glycolide)/hydroxyapatite/clindamycin core–shell nanosphere by liquid chromatography-tandem mass spectrometry. Program and the Book of Abstracts / Ninth Young Researchers Conference Materials Sciences and Engineering, December 20–22, 2010, Belgrade, Serbia. 2010;:19-19
Vuković, G., Lazić, S., Šunjka, D., Bursić, V., Šarčev, I., Vukomanović, M., Ignjatović, N.,& Uskoković, D. (2010). Determination of clindamycin in pig plasma after implantation of poly(D,Llactide-co-glycolide)/hydroxyapatite/clindamycin core–shell nanosphere by liquid chromatography-tandem mass spectrometry.
Program and the Book of Abstracts / Ninth Young Researchers Conference Materials Sciences and Engineering, December 20–22, 2010, Belgrade, SerbiaBelgrade : Institute of Technical Sciences of SASA., null, 19-19. 
Vuković Gorica, Lazić Sanja, Šunjka Dragana, Bursić Vojislava, Šarčev Ivan, Vukomanović Marija, Ignjatović Nenad, Uskoković Dragan, "Determination of clindamycin in pig plasma after implantation of poly(D,Llactide-co-glycolide)/hydroxyapatite/clindamycin core–shell nanosphere by liquid chromatography-tandem mass spectrometry" null (2010):19-19

DSpace software copyright © 2002-2015  DuraSpace
About DAIS - Digital Archive of the Serbian Academy of Sciences and Arts | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutionsAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About DAIS - Digital Archive of the Serbian Academy of Sciences and Arts | Send Feedback

re3dataOpenAIRERCUB