DAIS - Digital Archive of the Serbian Academy of Sciences and Arts
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrilic)
    • Serbian (Latin)
  • Login
View Item 
  •   DAIS
  • Институт техничких наука САНУ / Institute of Technical Sciences SASA
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
  • View Item
  •   DAIS
  • Институт техничких наука САНУ / Institute of Technical Sciences SASA
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Application of multiparametric cardiac measurement system in ejection fraction calculation

Thumbnail
2017
1816.pdf (738.0Kb)
Authors
Miletić, Marjan
Ivanović, Marija D.
Popović Maneski, Lana
Bojović, Boško
Conference object (Published version)
Metadata
Show full item record
Abstract
Ejection fraction (EF) is the most used parameter for characterisation of Heart Failure (HF) condition. EF is commonly calculated using echocardiography, which is an expensive non–invasive method and not used in primary healthcare. Systolic time intervals (STI) represent a non-invasive and inexpensive method for determination of EF[1, 2]. Heart failure (HF) is the single most expensive diagnosis in medicine. 2–3% of adult population in developed countries have HF diagnosis. It is not detectable by ECG test and it is commonly detected in a late stage, when the process is irreversible [2-5]. In this paper, a multiparametric cardiac measurement system for determination of STI is presented. Measurement system consists of sensors for simultaneous acquisition of electrocardiographic (ECG), phonocardiographic (PCG), photopletysmographic (PPG) and cardiovascular (CV) pulsation signals. CV pulsation signals are measured by long period grating (LPG) fiber-optic sensors[6]. Two non-invasive metho...ds for measuring systolic time intervals (STI) were applied on a set of 6 healthy volunteers, based on ECG, PCG and CV pulsation signals. CV pulsation signals were measured on carotide arthery with PPG and LPG sensors. In the first method, EF was calculated from the obtained STI signals, using CV carotide pulsations measured with the PPG sensor, giving EF values in the range from 0.60 to 0.68, with maximal standard deviation of 0.05. In the second method, EF was obtained using CV carotide pulsations measured with LPG sensor, giving EF values in the range from 0.60 to 0.66, with maximal standard deviation 0.06. Calculated values of EF with both methods were in the 0.55 to 0.75 range which corresponds to normal EF range in healthy individuals.

Keywords:
heart failure / ejection fraction calculation / systolic time intervals
Source:
Abstracts of Tutorial, Keynote, Invited Lectures, Progress Reports and Contributed Papers of the Sixth International School and Conference on Photonics PHOTONICA2017, 28 August – 1 September 2017, Belgrade Serbia, 2017, 112-112
Publisher:
  • Belgrade : Institute of Physics Belgrade

ISBN: 978-86-82441-46-5

[ Google Scholar ]
URI
http://dais.sanu.ac.rs/123456789/15422
Collections
  • ITN SANU - Opšta kolekcija / ITS SASA - General collection
Institution
Институт техничких наука САНУ / Institute of Technical Sciences SASA

DSpace software copyright © 2002-2015  DuraSpace
About DAIS - Digital Archive of the Serbian Academy of Sciences and Arts | Send Feedback

re3dataOpenAIRERCUB
 

 

All of DSpaceInstitutionsAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About DAIS - Digital Archive of the Serbian Academy of Sciences and Arts | Send Feedback

re3dataOpenAIRERCUB