Properties of different types of dry electrodes for wearable smart monitoring devices

Authorized Users Only
2020
Authors
Popović Maneski, Lana
Ivanović, Marija D.
Atanasoski, Vladimir
Miletić, Marjan
Zdolšek, Sanja
Bojović, Boško
Hadžievski, Ljupčo
Article (Published version)
Metadata
Show full item record
Abstract
Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI3...04). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.

Keywords:
dry electrodes / ECG / motion artifacts / signal quality / transient impedance / wearable monitor
Source:
Biomedical Engineering / Biomedizinische Technik, 2020, 65, 4, 405-415
Publisher:
  • Walter de Gruyter GmbH
Funding / projects:
  • Design of Robot as Assistive Technology in Treatement of Children with Developmental Disorders (RS-44008)
  • Photonics of micro and nano structured materials (RS-45010)
Note:
  • Peer-reviewed manuscript: https://hdl.handle.net/21.15107/rcub_dais_11598
Related info:
  • Version of
    https://hdl.handle.net/21.15107/rcub_dais_11598

DOI: 10.1515/bmt-2019-0167

ISSN: 1862-278X; 0013-5585

WoS: 000560600600003

Scopus: 2-s2.0-85083206490
[ Google Scholar ]
4
Handle
https://hdl.handle.net/21.15107/rcub_dais_10028
URI
https://dais.sanu.ac.rs/123456789/10028
Collections
  • ИТН САНУ - Општа колекција / ITS SASA - General collection
Institution/Community
Институт техничких наука САНУ / Institute of Technical Sciences of SASA
TY  - JOUR
AU  - Popović Maneski, Lana
AU  - Ivanović, Marija D.
AU  - Atanasoski, Vladimir
AU  - Miletić, Marjan
AU  - Zdolšek, Sanja
AU  - Bojović, Boško
AU  - Hadžievski, Ljupčo
PY  - 2020
UR  - https://dais.sanu.ac.rs/123456789/10028
AB  - Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.
PB  - Walter de Gruyter GmbH
T2  - Biomedical Engineering / Biomedizinische Technik
T1  - Properties of different types of dry electrodes for wearable smart monitoring devices
SP  - 405
EP  - 415
VL  - 65
IS  - 4
DO  - 10.1515/bmt-2019-0167
UR  - https://hdl.handle.net/21.15107/rcub_dais_10028
ER  - 
@article{
author = "Popović Maneski, Lana and Ivanović, Marija D. and Atanasoski, Vladimir and Miletić, Marjan and Zdolšek, Sanja and Bojović, Boško and Hadžievski, Ljupčo",
year = "2020",
abstract = "Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.",
publisher = "Walter de Gruyter GmbH",
journal = "Biomedical Engineering / Biomedizinische Technik",
title = "Properties of different types of dry electrodes for wearable smart monitoring devices",
pages = "405-415",
volume = "65",
number = "4",
doi = "10.1515/bmt-2019-0167",
url = "https://hdl.handle.net/21.15107/rcub_dais_10028"
}
Popović Maneski, L., Ivanović, M. D., Atanasoski, V., Miletić, M., Zdolšek, S., Bojović, B.,& Hadžievski, L.. (2020). Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik
Walter de Gruyter GmbH., 65(4), 405-415.
https://doi.org/10.1515/bmt-2019-0167
https://hdl.handle.net/21.15107/rcub_dais_10028
Popović Maneski L, Ivanović MD, Atanasoski V, Miletić M, Zdolšek S, Bojović B, Hadžievski L. Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik. 2020;65(4):405-415.
doi:10.1515/bmt-2019-0167
https://hdl.handle.net/21.15107/rcub_dais_10028 .
Popović Maneski, Lana, Ivanović, Marija D., Atanasoski, Vladimir, Miletić, Marjan, Zdolšek, Sanja, Bojović, Boško, Hadžievski, Ljupčo, "Properties of different types of dry electrodes for wearable smart monitoring devices" in Biomedical Engineering / Biomedizinische Technik, 65, no. 4 (2020):405-415,
https://doi.org/10.1515/bmt-2019-0167 .,
https://hdl.handle.net/21.15107/rcub_dais_10028 .

DSpace software copyright © 2002-2015  DuraSpace
About DAIS - Digital Archive of the Serbian Academy of Sciences and Arts | Send Feedback

CoreTrustSealre3dataOpenAIRERCUB
 

 

All of DSpaceInstitutions/communitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About DAIS - Digital Archive of the Serbian Academy of Sciences and Arts | Send Feedback

CoreTrustSealre3dataOpenAIRERCUB