Radulović, Katarina

Link to this page

Authority KeyName Variants
orcid::0000-0003-1003-2500
  • Radulović, Katarina (34)

Author's Bibliography

Stochastic Time Response and Ultimate Noise Performance of Adsorption-Based Microfluidic Biosensors

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš; Milovanović, Gradimir V.; Krstajić, Predrag M.

(Basel : MDPI AG, 2021)

TY  - JOUR
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
AU  - Milovanović, Gradimir V.
AU  - Krstajić, Predrag M.
PY  - 2021
UR  - https://dais.sanu.ac.rs/123456789/11638
AB  - In order to improve the interpretation of measurement results and to achieve the optimal performance of microfluidic biosensors, advanced mathematical models of their time response and noise are needed. The random nature of adsorption–desorption and mass transfer (MT) processes that generate the sensor response makes the sensor output signal inherently stochastic and necessitates the use of a stochastic approach in sensor response analysis. We present a stochastic model of the sensor time response, which takes into account the coupling of adsorption–desorption and MT processes. It is used for the analysis of response kinetics and ultimate noise performance of protein biosensors. We show that slow MT not only decelerates the response kinetics, but also increases the noise and decreases the sensor’s maximal achievable signal-to-noise ratio, thus degrading the ultimate sensor performance, including the minimal detectable/quantifiable analyte concentration. The results illustrate the significance of the presented model for the correct interpretation of measurement data, for the estimation of sensors’ noise performance metrics important for reliable analyte detection/quantification, as well as for sensor optimization in terms of the lower detection/quantification limit. They are also incentives for the further investigation of the MT influence in nanoscale sensors, as a possible cause of false-negative results in analyte detection experiments.
PB  - Basel : MDPI AG
T2  - Biosensors
T1  - Stochastic Time Response and Ultimate Noise Performance of Adsorption-Based Microfluidic Biosensors
SP  - 194
VL  - 11
IS  - 6
DO  - 10.3390/bios11060194
UR  - https://hdl.handle.net/21.15107/rcub_dais_11638
ER  - 
@article{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš and Milovanović, Gradimir V. and Krstajić, Predrag M.",
year = "2021",
abstract = "In order to improve the interpretation of measurement results and to achieve the optimal performance of microfluidic biosensors, advanced mathematical models of their time response and noise are needed. The random nature of adsorption–desorption and mass transfer (MT) processes that generate the sensor response makes the sensor output signal inherently stochastic and necessitates the use of a stochastic approach in sensor response analysis. We present a stochastic model of the sensor time response, which takes into account the coupling of adsorption–desorption and MT processes. It is used for the analysis of response kinetics and ultimate noise performance of protein biosensors. We show that slow MT not only decelerates the response kinetics, but also increases the noise and decreases the sensor’s maximal achievable signal-to-noise ratio, thus degrading the ultimate sensor performance, including the minimal detectable/quantifiable analyte concentration. The results illustrate the significance of the presented model for the correct interpretation of measurement data, for the estimation of sensors’ noise performance metrics important for reliable analyte detection/quantification, as well as for sensor optimization in terms of the lower detection/quantification limit. They are also incentives for the further investigation of the MT influence in nanoscale sensors, as a possible cause of false-negative results in analyte detection experiments.",
publisher = "Basel : MDPI AG",
journal = "Biosensors",
title = "Stochastic Time Response and Ultimate Noise Performance of Adsorption-Based Microfluidic Biosensors",
pages = "194",
volume = "11",
number = "6",
doi = "10.3390/bios11060194",
url = "https://hdl.handle.net/21.15107/rcub_dais_11638"
}
Jokić, I., Đurić, Z. G., Radulović, K., Frantlović, M., Milovanović, G. V.,& Krstajić, P. M.. (2021). Stochastic Time Response and Ultimate Noise Performance of Adsorption-Based Microfluidic Biosensors. in Biosensors
Basel : MDPI AG., 11(6), 194.
https://doi.org/10.3390/bios11060194
https://hdl.handle.net/21.15107/rcub_dais_11638
Jokić I, Đurić ZG, Radulović K, Frantlović M, Milovanović GV, Krstajić PM. Stochastic Time Response and Ultimate Noise Performance of Adsorption-Based Microfluidic Biosensors. in Biosensors. 2021;11(6):194.
doi:10.3390/bios11060194
https://hdl.handle.net/21.15107/rcub_dais_11638 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, Milovanović, Gradimir V., Krstajić, Predrag M., "Stochastic Time Response and Ultimate Noise Performance of Adsorption-Based Microfluidic Biosensors" in Biosensors, 11, no. 6 (2021):194,
https://doi.org/10.3390/bios11060194 .,
https://hdl.handle.net/21.15107/rcub_dais_11638 .
2
2

Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase

Vuković, Marina; Dinić, Ivana; Nikolić, Marko G.; Marinković, Bojan A.; Costa, Antonio Mario Leal Martins; Radulović, Katarina; Milošević, Olivera; Mančić, Lidija

(Springer, 2020)

TY  - JOUR
AU  - Vuković, Marina
AU  - Dinić, Ivana
AU  - Nikolić, Marko G.
AU  - Marinković, Bojan A.
AU  - Costa, Antonio Mario Leal Martins
AU  - Radulović, Katarina
AU  - Milošević, Olivera
AU  - Mančić, Lidija
PY  - 2020
UR  - https://dais.sanu.ac.rs/123456789/6912
AB  - Up-converting NaYF4:Yb,Er nanoparticles were obtained by polymer-assisted solvothermal synthesis using a common solution of hydrated RE nitrates in ethanol or ethylene glycol. It was shown that polymer choice (polyacrylic acid—PAA, polyvinylpyrrolidone—PVP and chitosan—CS) controls the size and shape of NaYF4:Yb,Er nanoparticles, while the solvent type and pH value affect their crystallinity. Consequently, the spherical nanoparticles of a cubic (α) phase, the average size of which ranged from 60 to 140 nm, were obtained either when PVP/ethanol or PVP/ethylene glycol were used solely during synthesis, whereas NaOH addition induced hexagonal (β) phase nucleation. The formation of the hierarchically organized spherical aggregates and nanofoils was observed when CS and PAA were used during synthesis, respectively. The average crystallite size, microstrain, doping level, lattice parameters, as well as, the presence of the certain ligands on the particle surface were determined and correlated with the intensity of visible-light emission observed under 980 nm laser-diode excitation.
PB  - Springer
T2  - Bulletin of Materials Science
T1  - Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase
SP  - 2
VL  - 43
IS  - 1
DO  - 10.1007/s12034-019-1975-1
UR  - https://hdl.handle.net/21.15107/rcub_dais_6912
ER  - 
@article{
author = "Vuković, Marina and Dinić, Ivana and Nikolić, Marko G. and Marinković, Bojan A. and Costa, Antonio Mario Leal Martins and Radulović, Katarina and Milošević, Olivera and Mančić, Lidija",
year = "2020",
abstract = "Up-converting NaYF4:Yb,Er nanoparticles were obtained by polymer-assisted solvothermal synthesis using a common solution of hydrated RE nitrates in ethanol or ethylene glycol. It was shown that polymer choice (polyacrylic acid—PAA, polyvinylpyrrolidone—PVP and chitosan—CS) controls the size and shape of NaYF4:Yb,Er nanoparticles, while the solvent type and pH value affect their crystallinity. Consequently, the spherical nanoparticles of a cubic (α) phase, the average size of which ranged from 60 to 140 nm, were obtained either when PVP/ethanol or PVP/ethylene glycol were used solely during synthesis, whereas NaOH addition induced hexagonal (β) phase nucleation. The formation of the hierarchically organized spherical aggregates and nanofoils was observed when CS and PAA were used during synthesis, respectively. The average crystallite size, microstrain, doping level, lattice parameters, as well as, the presence of the certain ligands on the particle surface were determined and correlated with the intensity of visible-light emission observed under 980 nm laser-diode excitation.",
publisher = "Springer",
journal = "Bulletin of Materials Science",
title = "Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase",
pages = "2",
volume = "43",
number = "1",
doi = "10.1007/s12034-019-1975-1",
url = "https://hdl.handle.net/21.15107/rcub_dais_6912"
}
Vuković, M., Dinić, I., Nikolić, M. G., Marinković, B. A., Costa, A. M. L. M., Radulović, K., Milošević, O.,& Mančić, L.. (2020). Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase. in Bulletin of Materials Science
Springer., 43(1), 2.
https://doi.org/10.1007/s12034-019-1975-1
https://hdl.handle.net/21.15107/rcub_dais_6912
Vuković M, Dinić I, Nikolić MG, Marinković BA, Costa AMLM, Radulović K, Milošević O, Mančić L. Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase. in Bulletin of Materials Science. 2020;43(1):2.
doi:10.1007/s12034-019-1975-1
https://hdl.handle.net/21.15107/rcub_dais_6912 .
Vuković, Marina, Dinić, Ivana, Nikolić, Marko G., Marinković, Bojan A., Costa, Antonio Mario Leal Martins, Radulović, Katarina, Milošević, Olivera, Mančić, Lidija, "Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase" in Bulletin of Materials Science, 43, no. 1 (2020):2,
https://doi.org/10.1007/s12034-019-1975-1 .,
https://hdl.handle.net/21.15107/rcub_dais_6912 .
5
2
5

Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase

Vuković, Marina; Dinić, Ivana; Nikolić, Marko G.; Marinković, Bojan A.; Costa, Antonio Mario Leal Martins; Radulović, Katarina; Milošević, Olivera; Mančić, Lidija

(Springer, 2020)

TY  - JOUR
AU  - Vuković, Marina
AU  - Dinić, Ivana
AU  - Nikolić, Marko G.
AU  - Marinković, Bojan A.
AU  - Costa, Antonio Mario Leal Martins
AU  - Radulović, Katarina
AU  - Milošević, Olivera
AU  - Mančić, Lidija
PY  - 2020
UR  - https://dais.sanu.ac.rs/123456789/6911
AB  - Up-converting NaYF4:Yb,Er nanoparticles were obtained by polymer-assisted solvothermal synthesis using a common solution of hydrated RE nitrates in ethanol or ethylene glycol. It was shown that polymer choice (polyacrylic acid—PAA, polyvinylpyrrolidone—PVP and chitosan—CS) controls the size and shape of NaYF4:Yb,Er nanoparticles, while the solvent type and pH value affect their crystallinity. Consequently, the spherical nanoparticles of a cubic (α) phase, the average size of which ranged from 60 to 140 nm, were obtained either when PVP/ethanol or PVP/ethylene glycol were used solely during synthesis, whereas NaOH addition induced hexagonal (β) phase nucleation. The formation of the hierarchically organized spherical aggregates and nanofoils was observed when CS and PAA were used during synthesis, respectively. The average crystallite size, microstrain, doping level, lattice parameters, as well as, the presence of the certain ligands on the particle surface were determined and correlated with the intensity of visible-light emission observed under 980 nm laser-diode excitation.
PB  - Springer
T2  - Bulletin of Materials Science
T1  - Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase
SP  - 2
VL  - 43
IS  - 1
DO  - 10.1007/s12034-019-1975-1
UR  - https://hdl.handle.net/21.15107/rcub_dais_6911
ER  - 
@article{
author = "Vuković, Marina and Dinić, Ivana and Nikolić, Marko G. and Marinković, Bojan A. and Costa, Antonio Mario Leal Martins and Radulović, Katarina and Milošević, Olivera and Mančić, Lidija",
year = "2020",
abstract = "Up-converting NaYF4:Yb,Er nanoparticles were obtained by polymer-assisted solvothermal synthesis using a common solution of hydrated RE nitrates in ethanol or ethylene glycol. It was shown that polymer choice (polyacrylic acid—PAA, polyvinylpyrrolidone—PVP and chitosan—CS) controls the size and shape of NaYF4:Yb,Er nanoparticles, while the solvent type and pH value affect their crystallinity. Consequently, the spherical nanoparticles of a cubic (α) phase, the average size of which ranged from 60 to 140 nm, were obtained either when PVP/ethanol or PVP/ethylene glycol were used solely during synthesis, whereas NaOH addition induced hexagonal (β) phase nucleation. The formation of the hierarchically organized spherical aggregates and nanofoils was observed when CS and PAA were used during synthesis, respectively. The average crystallite size, microstrain, doping level, lattice parameters, as well as, the presence of the certain ligands on the particle surface were determined and correlated with the intensity of visible-light emission observed under 980 nm laser-diode excitation.",
publisher = "Springer",
journal = "Bulletin of Materials Science",
title = "Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase",
pages = "2",
volume = "43",
number = "1",
doi = "10.1007/s12034-019-1975-1",
url = "https://hdl.handle.net/21.15107/rcub_dais_6911"
}
Vuković, M., Dinić, I., Nikolić, M. G., Marinković, B. A., Costa, A. M. L. M., Radulović, K., Milošević, O.,& Mančić, L.. (2020). Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase. in Bulletin of Materials Science
Springer., 43(1), 2.
https://doi.org/10.1007/s12034-019-1975-1
https://hdl.handle.net/21.15107/rcub_dais_6911
Vuković M, Dinić I, Nikolić MG, Marinković BA, Costa AMLM, Radulović K, Milošević O, Mančić L. Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase. in Bulletin of Materials Science. 2020;43(1):2.
doi:10.1007/s12034-019-1975-1
https://hdl.handle.net/21.15107/rcub_dais_6911 .
Vuković, Marina, Dinić, Ivana, Nikolić, Marko G., Marinković, Bojan A., Costa, Antonio Mario Leal Martins, Radulović, Katarina, Milošević, Olivera, Mančić, Lidija, "Effects of different polymers and solvents on crystallization of theNaYF4:Yb/Er phase" in Bulletin of Materials Science, 43, no. 1 (2020):2,
https://doi.org/10.1007/s12034-019-1975-1 .,
https://hdl.handle.net/21.15107/rcub_dais_6911 .
5
2
5

Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš; Krstajić, Predrag

(Institute of Electrical and Electronics Engineers (IEEE), 2019)

TY  - CONF
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
AU  - Krstajić, Predrag
PY  - 2019
UR  - https://dais.sanu.ac.rs/123456789/6918
AB  - Real-time in situ operation of bio/chemical sensors assumes detection of chemical substances or biological specimens in samples of complex composition. Since sensor selectivity cannot be ideal, adsorption of particles other than target particles inevitably occur on the sensing surface. That affects the sensor response and its intrinsic fluctuations which are caused by stochastic fluctuations of the numbers of adsorbed particles of all the adsorbing substances. In microfluidic sensors, such response fluctuations are a result of coupled adsorption, desorption and mass transfer (convection and diffusion) processes of analyte particles. Analysis of these fluctuations is important because they constitute the adsorption-desorption noise, which limits the sensing performance. In this work we perform the analysis of fluctuations by using a stochastic model of sensor response after the steady state is reached, in the case of two-analyte adsorption, considering mass transfer processes. The results enable estimation of the ultimate sensing performance of adsorption-based microfluidic bio/chemical sensors of different sensing areas, operating in bianalyte mixture environments.
PB  - Institute of Electrical and Electronics Engineers (IEEE)
C3  - 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings
T1  - Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures
SP  - 161
EP  - 164
DO  - 10.1109/MIEL.2019.8889579
UR  - https://hdl.handle.net/21.15107/rcub_dais_6918
ER  - 
@conference{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš and Krstajić, Predrag",
year = "2019",
abstract = "Real-time in situ operation of bio/chemical sensors assumes detection of chemical substances or biological specimens in samples of complex composition. Since sensor selectivity cannot be ideal, adsorption of particles other than target particles inevitably occur on the sensing surface. That affects the sensor response and its intrinsic fluctuations which are caused by stochastic fluctuations of the numbers of adsorbed particles of all the adsorbing substances. In microfluidic sensors, such response fluctuations are a result of coupled adsorption, desorption and mass transfer (convection and diffusion) processes of analyte particles. Analysis of these fluctuations is important because they constitute the adsorption-desorption noise, which limits the sensing performance. In this work we perform the analysis of fluctuations by using a stochastic model of sensor response after the steady state is reached, in the case of two-analyte adsorption, considering mass transfer processes. The results enable estimation of the ultimate sensing performance of adsorption-based microfluidic bio/chemical sensors of different sensing areas, operating in bianalyte mixture environments.",
publisher = "Institute of Electrical and Electronics Engineers (IEEE)",
journal = "2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings",
title = "Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures",
pages = "161-164",
doi = "10.1109/MIEL.2019.8889579",
url = "https://hdl.handle.net/21.15107/rcub_dais_6918"
}
Jokić, I., Đurić, Z. G., Radulović, K., Frantlović, M.,& Krstajić, P.. (2019). Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures. in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings
Institute of Electrical and Electronics Engineers (IEEE)., 161-164.
https://doi.org/10.1109/MIEL.2019.8889579
https://hdl.handle.net/21.15107/rcub_dais_6918
Jokić I, Đurić ZG, Radulović K, Frantlović M, Krstajić P. Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures. in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings. 2019;:161-164.
doi:10.1109/MIEL.2019.8889579
https://hdl.handle.net/21.15107/rcub_dais_6918 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, Krstajić, Predrag, "Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures" in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings (2019):161-164,
https://doi.org/10.1109/MIEL.2019.8889579 .,
https://hdl.handle.net/21.15107/rcub_dais_6918 .

Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors

Jokić, Ivana; Radulović, Katarina; Frantlović, Miloš; Đurić, Zoran G.; Cvetanović Zobenica, Katarina; Krstajić, Predrag

(Belgrade : ETRAN, 2019)

TY  - CONF
AU  - Jokić, Ivana
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
AU  - Đurić, Zoran G.
AU  - Cvetanović Zobenica, Katarina
AU  - Krstajić, Predrag
PY  - 2019
UR  - https://dais.sanu.ac.rs/123456789/6961
AB  - Detection limits in microfluidic chemical and biological sensors, which determine the range of analyte concentrations reliably detectable by the sensor, are important sensor parameters. The lower limit of detection, defined as the lowest concentration that can be distinguished from noise, has its minimum determined by the fundamental adsorption-desorption (AD) noise, inevitable in adsorption-based devices. In this work, we analyze this fundamental detection limit, particularly considering the influence of mass transfer processes in microfluidic devices. For that purpose, we derive the expression for the sensor’s signal-to-noise ratio (SNR), which takes into account the AD noise, and then the equation for the minimal analyte concentration at which the SNR has a sufficiently high value for reliable analyte detection. Subsequently, we analyze the mass transfer influence on the sensor’s maximal achievable signal-to-noise ratio and on the fundamental detection limit. The results of the analysis show a significant mass transfer influence on these important sensor performance metrics. They also provide guidelines for achieving the sensor’s best possible detection performance through the optimization of the sensor design and operating conditions.
PB  - Belgrade : ETRAN
PB  - Belgrade :Academic Mind
C3  - Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine
T1  - Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors
SP  - 571
EP  - 574
UR  - https://hdl.handle.net/21.15107/rcub_dais_6961
ER  - 
@conference{
author = "Jokić, Ivana and Radulović, Katarina and Frantlović, Miloš and Đurić, Zoran G. and Cvetanović Zobenica, Katarina and Krstajić, Predrag",
year = "2019",
abstract = "Detection limits in microfluidic chemical and biological sensors, which determine the range of analyte concentrations reliably detectable by the sensor, are important sensor parameters. The lower limit of detection, defined as the lowest concentration that can be distinguished from noise, has its minimum determined by the fundamental adsorption-desorption (AD) noise, inevitable in adsorption-based devices. In this work, we analyze this fundamental detection limit, particularly considering the influence of mass transfer processes in microfluidic devices. For that purpose, we derive the expression for the sensor’s signal-to-noise ratio (SNR), which takes into account the AD noise, and then the equation for the minimal analyte concentration at which the SNR has a sufficiently high value for reliable analyte detection. Subsequently, we analyze the mass transfer influence on the sensor’s maximal achievable signal-to-noise ratio and on the fundamental detection limit. The results of the analysis show a significant mass transfer influence on these important sensor performance metrics. They also provide guidelines for achieving the sensor’s best possible detection performance through the optimization of the sensor design and operating conditions.",
publisher = "Belgrade : ETRAN, Belgrade :Academic Mind",
journal = "Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine",
title = "Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors",
pages = "571-574",
url = "https://hdl.handle.net/21.15107/rcub_dais_6961"
}
Jokić, I., Radulović, K., Frantlović, M., Đurić, Z. G., Cvetanović Zobenica, K.,& Krstajić, P.. (2019). Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors. in Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine
Belgrade : ETRAN., 571-574.
https://hdl.handle.net/21.15107/rcub_dais_6961
Jokić I, Radulović K, Frantlović M, Đurić ZG, Cvetanović Zobenica K, Krstajić P. Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors. in Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine. 2019;:571-574.
https://hdl.handle.net/21.15107/rcub_dais_6961 .
Jokić, Ivana, Radulović, Katarina, Frantlović, Miloš, Đurić, Zoran G., Cvetanović Zobenica, Katarina, Krstajić, Predrag, "Analysis of the Fundamental Detection Limit in Microfluidic Chemical and Biological Sensors" in Proceedings of Papers – 6th International Conference on Electrical, Electronic and Computing Engineering, IcETRAN 2019, Silver Lake, Serbia, June 03 – 06, 2019 / Zbornik radova - 63. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 03 – 06. juna, 2019. godine (2019):571-574,
https://hdl.handle.net/21.15107/rcub_dais_6961 .

Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš; Krstajić, Predrag

(Institute of Electrical and Electronics Engineers (IEEE), 2019)

TY  - CONF
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
AU  - Krstajić, Predrag
PY  - 2019
UR  - https://dais.sanu.ac.rs/123456789/6909
AB  - Real-time in situ operation of bio/chemical sensors assumes detection of chemical substances or biological specimens in samples of complex composition. Since sensor selectivity cannot be ideal, adsorption of particles other than target particles inevitably occur on the sensing surface. That affects the sensor response and its intrinsic fluctuations which are caused by stochastic fluctuations of the numbers of adsorbed particles of all the adsorbing substances. In microfluidic sensors, such response fluctuations are a result of coupled adsorption, desorption and mass transfer (convection and diffusion) processes of analyte particles. Analysis of these fluctuations is important because they constitute the adsorption-desorption noise, which limits the sensing performance. In this work we perform the analysis of fluctuations by using a stochastic model of sensor response after the steady state is reached, in the case of two-analyte adsorption, considering mass transfer processes. The results enable estimation of the ultimate sensing performance of adsorption-based microfluidic bio/chemical sensors of different sensing areas, operating in bianalyte mixture environments.
PB  - Institute of Electrical and Electronics Engineers (IEEE)
C3  - 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings
T1  - Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures
SP  - 161
EP  - 164
DO  - 10.1109/MIEL.2019.8889579
UR  - https://hdl.handle.net/21.15107/rcub_dais_6909
ER  - 
@conference{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš and Krstajić, Predrag",
year = "2019",
abstract = "Real-time in situ operation of bio/chemical sensors assumes detection of chemical substances or biological specimens in samples of complex composition. Since sensor selectivity cannot be ideal, adsorption of particles other than target particles inevitably occur on the sensing surface. That affects the sensor response and its intrinsic fluctuations which are caused by stochastic fluctuations of the numbers of adsorbed particles of all the adsorbing substances. In microfluidic sensors, such response fluctuations are a result of coupled adsorption, desorption and mass transfer (convection and diffusion) processes of analyte particles. Analysis of these fluctuations is important because they constitute the adsorption-desorption noise, which limits the sensing performance. In this work we perform the analysis of fluctuations by using a stochastic model of sensor response after the steady state is reached, in the case of two-analyte adsorption, considering mass transfer processes. The results enable estimation of the ultimate sensing performance of adsorption-based microfluidic bio/chemical sensors of different sensing areas, operating in bianalyte mixture environments.",
publisher = "Institute of Electrical and Electronics Engineers (IEEE)",
journal = "2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings",
title = "Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures",
pages = "161-164",
doi = "10.1109/MIEL.2019.8889579",
url = "https://hdl.handle.net/21.15107/rcub_dais_6909"
}
Jokić, I., Đurić, Z. G., Radulović, K., Frantlović, M.,& Krstajić, P.. (2019). Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures. in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings
Institute of Electrical and Electronics Engineers (IEEE)., 161-164.
https://doi.org/10.1109/MIEL.2019.8889579
https://hdl.handle.net/21.15107/rcub_dais_6909
Jokić I, Đurić ZG, Radulović K, Frantlović M, Krstajić P. Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures. in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings. 2019;:161-164.
doi:10.1109/MIEL.2019.8889579
https://hdl.handle.net/21.15107/rcub_dais_6909 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, Krstajić, Predrag, "Analysis of Intrinsic Stochastic Fluctuations of the Time Response of Adsorption-Based Microfluidic Bio/Chemical Sensors: the Case of Bianalyte Mixtures" in 2019 IEEE 31st International Conference on Microelectronics, MIEL 2019 - Proceedings (2019):161-164,
https://doi.org/10.1109/MIEL.2019.8889579 .,
https://hdl.handle.net/21.15107/rcub_dais_6909 .

Analysis of Stochastic Time Response of Microfluidic Biosensors in the Case of Competitive Adsorption of Two Analytes

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš

(Basel : MDPI, 2018)

TY  - CONF
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
PY  - 2018
UR  - https://www.mdpi.com/2504-3900/2/13/991
UR  - https://dais.sanu.ac.rs/123456789/4715
AB  - A model of stochastic time response of adsorption-based microfluidic biosensors is presented, that considers the competitive adsorption-desorption process coupled with mass transfer of two analytes. By using the model we analyze the expected value of the adsorbed particles number of each analyte, which determine the sensor response kinetics. The comparison with the case when only one analyte exists is used for investigation of the influence of competitive adsorption on the sensor response. The response kinetics analyzed by using the stochastic model is compared with the kinetics predicted by the deterministic response model. The results are useful for optimization of micro/nanosensors intended for detection of substances in ultra-low concentrations in complex samples.
PB  - Basel : MDPI
C3  - Proceedings, Volume 2, Eurosensors 2018
T1  - Analysis of Stochastic Time Response of Microfluidic Biosensors in the Case of Competitive Adsorption of Two Analytes
SP  - 991
VL  - 2
IS  - 13
DO  - 10.3390/proceedings2130991
UR  - https://hdl.handle.net/21.15107/rcub_dais_4715
ER  - 
@conference{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš",
year = "2018",
abstract = "A model of stochastic time response of adsorption-based microfluidic biosensors is presented, that considers the competitive adsorption-desorption process coupled with mass transfer of two analytes. By using the model we analyze the expected value of the adsorbed particles number of each analyte, which determine the sensor response kinetics. The comparison with the case when only one analyte exists is used for investigation of the influence of competitive adsorption on the sensor response. The response kinetics analyzed by using the stochastic model is compared with the kinetics predicted by the deterministic response model. The results are useful for optimization of micro/nanosensors intended for detection of substances in ultra-low concentrations in complex samples.",
publisher = "Basel : MDPI",
journal = "Proceedings, Volume 2, Eurosensors 2018",
title = "Analysis of Stochastic Time Response of Microfluidic Biosensors in the Case of Competitive Adsorption of Two Analytes",
pages = "991",
volume = "2",
number = "13",
doi = "10.3390/proceedings2130991",
url = "https://hdl.handle.net/21.15107/rcub_dais_4715"
}
Jokić, I., Đurić, Z. G., Radulović, K.,& Frantlović, M.. (2018). Analysis of Stochastic Time Response of Microfluidic Biosensors in the Case of Competitive Adsorption of Two Analytes. in Proceedings, Volume 2, Eurosensors 2018
Basel : MDPI., 2(13), 991.
https://doi.org/10.3390/proceedings2130991
https://hdl.handle.net/21.15107/rcub_dais_4715
Jokić I, Đurić ZG, Radulović K, Frantlović M. Analysis of Stochastic Time Response of Microfluidic Biosensors in the Case of Competitive Adsorption of Two Analytes. in Proceedings, Volume 2, Eurosensors 2018. 2018;2(13):991.
doi:10.3390/proceedings2130991
https://hdl.handle.net/21.15107/rcub_dais_4715 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, "Analysis of Stochastic Time Response of Microfluidic Biosensors in the Case of Competitive Adsorption of Two Analytes" in Proceedings, Volume 2, Eurosensors 2018, 2, no. 13 (2018):991,
https://doi.org/10.3390/proceedings2130991 .,
https://hdl.handle.net/21.15107/rcub_dais_4715 .
2

Steady-state analysis of stochastic time response of chemical and biological microfluidic sensors

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš; Krstajić, Predrag; Cvetanović Zobenica, Katarina

(ETRAN, 2018)

TY  - CONF
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
AU  - Krstajić, Predrag
AU  - Cvetanović Zobenica, Katarina
PY  - 2018
UR  - https://www.etran.rs/2018/IcETRAN/News/IcETRAN%20sumarni%20program%20sekcija_Ver.%204.3%20(1).pdf
UR  - https://dais.sanu.ac.rs/123456789/4630
AB  - In this paper we first give a short review of two stochastic models describing both the expected value and variance of the random number of adsorbed particles in microfluidic adsorption-based chemical and biological sensors. One model takes into account the influence of coupling of stochastic adsorptiondesorption processes and mass transfer on the change of the number of adsorbed particles, while the other neglects the influence of mass transfer. Subsequently, by using the two models, we perform the analysis of the expected value and variance, as well as the sensor's signal-to-noise ratio, after reaching the steady state of all transient processes. We compare the results obtained by using the different models, and determine conditions for their application. We estimate the influences of the sensing surface area and the concentration of target particles on statistical parameters of sensor response and signal-to-noise ratio, considering the cases where mass transfer is significant, and those where it is not. We particularly analyze the mass transfer influence on the expected value, variance and signal-to-noise ratio. Such analysis does not exist in the available literature. The presented analysis yields new knowledge about the stochastic response of adsorption-based sensors, and it is significant for their optimization in order to achieve reliable analyte detection and improved sensing performance.
PB  - ETRAN
C3  - IcETRAN & ETRAN 2018, Palić 11-14. 06. 2018: Program
T1  - Steady-state analysis of stochastic time response of chemical and biological microfluidic sensors
UR  - https://hdl.handle.net/21.15107/rcub_dais_4630
ER  - 
@conference{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš and Krstajić, Predrag and Cvetanović Zobenica, Katarina",
year = "2018",
abstract = "In this paper we first give a short review of two stochastic models describing both the expected value and variance of the random number of adsorbed particles in microfluidic adsorption-based chemical and biological sensors. One model takes into account the influence of coupling of stochastic adsorptiondesorption processes and mass transfer on the change of the number of adsorbed particles, while the other neglects the influence of mass transfer. Subsequently, by using the two models, we perform the analysis of the expected value and variance, as well as the sensor's signal-to-noise ratio, after reaching the steady state of all transient processes. We compare the results obtained by using the different models, and determine conditions for their application. We estimate the influences of the sensing surface area and the concentration of target particles on statistical parameters of sensor response and signal-to-noise ratio, considering the cases where mass transfer is significant, and those where it is not. We particularly analyze the mass transfer influence on the expected value, variance and signal-to-noise ratio. Such analysis does not exist in the available literature. The presented analysis yields new knowledge about the stochastic response of adsorption-based sensors, and it is significant for their optimization in order to achieve reliable analyte detection and improved sensing performance.",
publisher = "ETRAN",
journal = "IcETRAN & ETRAN 2018, Palić 11-14. 06. 2018: Program",
title = "Steady-state analysis of stochastic time response of chemical and biological microfluidic sensors",
url = "https://hdl.handle.net/21.15107/rcub_dais_4630"
}
Jokić, I., Đurić, Z. G., Radulović, K., Frantlović, M., Krstajić, P.,& Cvetanović Zobenica, K.. (2018). Steady-state analysis of stochastic time response of chemical and biological microfluidic sensors. in IcETRAN & ETRAN 2018, Palić 11-14. 06. 2018: Program
ETRAN..
https://hdl.handle.net/21.15107/rcub_dais_4630
Jokić I, Đurić ZG, Radulović K, Frantlović M, Krstajić P, Cvetanović Zobenica K. Steady-state analysis of stochastic time response of chemical and biological microfluidic sensors. in IcETRAN & ETRAN 2018, Palić 11-14. 06. 2018: Program. 2018;.
https://hdl.handle.net/21.15107/rcub_dais_4630 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, Krstajić, Predrag, Cvetanović Zobenica, Katarina, "Steady-state analysis of stochastic time response of chemical and biological microfluidic sensors" in IcETRAN & ETRAN 2018, Palić 11-14. 06. 2018: Program (2018),
https://hdl.handle.net/21.15107/rcub_dais_4630 .

Deterministic versus Stochastic Analysis of Competitive Adsorption in Equilibrium in Microfluidic Biosensors

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš

(Elsevier, 2018)

TY  - JOUR
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
PY  - 2018
UR  - http://www.sciencedirect.com/science/article/pii/S2214785318309167
UR  - https://dais.sanu.ac.rs/123456789/4550
AB  - We investigate the stochastic sensor response in equilibrium, taking into account competitive adsorption and mass transfer of analyte particles in a microfluidic biosensor chamber. After presentation of the stochastic model, we perform the analysis of the equilibrium response expected value as a function of the sensing area and the competitor molecules concentrations. By comparison with the deterministic value of the sensor response, the limits of applicability of the deterministic approach are investigated. The results of the presented analysis enable better interpretation of measurement results obtained by using sensors with micro/nanoscale sensing surface, as well as optimization of their design and operating conditions.
PB  - Elsevier
T2  - Materials Today: Proceedings
T1  - Deterministic versus Stochastic Analysis of Competitive Adsorption in Equilibrium in Microfluidic Biosensors
SP  - 16006
EP  - 16011
VL  - 5
IS  - 8, Part 2
DO  - 10.1016/j.matpr.2018.05.045
UR  - https://hdl.handle.net/21.15107/rcub_dais_4550
ER  - 
@article{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš",
year = "2018",
abstract = "We investigate the stochastic sensor response in equilibrium, taking into account competitive adsorption and mass transfer of analyte particles in a microfluidic biosensor chamber. After presentation of the stochastic model, we perform the analysis of the equilibrium response expected value as a function of the sensing area and the competitor molecules concentrations. By comparison with the deterministic value of the sensor response, the limits of applicability of the deterministic approach are investigated. The results of the presented analysis enable better interpretation of measurement results obtained by using sensors with micro/nanoscale sensing surface, as well as optimization of their design and operating conditions.",
publisher = "Elsevier",
journal = "Materials Today: Proceedings",
title = "Deterministic versus Stochastic Analysis of Competitive Adsorption in Equilibrium in Microfluidic Biosensors",
pages = "16006-16011",
volume = "5",
number = "8, Part 2",
doi = "10.1016/j.matpr.2018.05.045",
url = "https://hdl.handle.net/21.15107/rcub_dais_4550"
}
Jokić, I., Đurić, Z. G., Radulović, K.,& Frantlović, M.. (2018). Deterministic versus Stochastic Analysis of Competitive Adsorption in Equilibrium in Microfluidic Biosensors. in Materials Today: Proceedings
Elsevier., 5(8, Part 2), 16006-16011.
https://doi.org/10.1016/j.matpr.2018.05.045
https://hdl.handle.net/21.15107/rcub_dais_4550
Jokić I, Đurić ZG, Radulović K, Frantlović M. Deterministic versus Stochastic Analysis of Competitive Adsorption in Equilibrium in Microfluidic Biosensors. in Materials Today: Proceedings. 2018;5(8, Part 2):16006-16011.
doi:10.1016/j.matpr.2018.05.045
https://hdl.handle.net/21.15107/rcub_dais_4550 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, "Deterministic versus Stochastic Analysis of Competitive Adsorption in Equilibrium in Microfluidic Biosensors" in Materials Today: Proceedings, 5, no. 8, Part 2 (2018):16006-16011,
https://doi.org/10.1016/j.matpr.2018.05.045 .,
https://hdl.handle.net/21.15107/rcub_dais_4550 .

Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš

(IEEE, 2017)

TY  - CONF
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
PY  - 2017
UR  - https://dais.sanu.ac.rs/123456789/3684
AB  - An approximate model for efficient analysis of stochastic time response of microfluidic biosensors is presented, that considers a random AD process coupled with mass transfer (convection and diffusion) of target substance particles. The deterministic model of sensor response is also reviewed. We perform the analysis of the mass transfer influence on the kinetics and the steady-state value of the response calculated according to the two models (deterministic and stochastic). The results are presented for the sensors with different micro/nanoscale active surfaces. The comparison of the responses obtained by using the two models can be utilized to distinguish the cases in which the application of the deterministic model is justified from those in which the stochastic model is necessary. The presented findings enable more accurate interpretation of measurement results obtained by using micro/nanobiosensors.
PB  - IEEE
C3  - 2017 IEEE 30th International Conference on Microelectronics (MIEL)
T1  - Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer
SP  - 127
EP  - 130
DO  - 10.1109/MIEL.2017.8190084
UR  - https://hdl.handle.net/21.15107/rcub_dais_3684
ER  - 
@conference{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš",
year = "2017",
abstract = "An approximate model for efficient analysis of stochastic time response of microfluidic biosensors is presented, that considers a random AD process coupled with mass transfer (convection and diffusion) of target substance particles. The deterministic model of sensor response is also reviewed. We perform the analysis of the mass transfer influence on the kinetics and the steady-state value of the response calculated according to the two models (deterministic and stochastic). The results are presented for the sensors with different micro/nanoscale active surfaces. The comparison of the responses obtained by using the two models can be utilized to distinguish the cases in which the application of the deterministic model is justified from those in which the stochastic model is necessary. The presented findings enable more accurate interpretation of measurement results obtained by using micro/nanobiosensors.",
publisher = "IEEE",
journal = "2017 IEEE 30th International Conference on Microelectronics (MIEL)",
title = "Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer",
pages = "127-130",
doi = "10.1109/MIEL.2017.8190084",
url = "https://hdl.handle.net/21.15107/rcub_dais_3684"
}
Jokić, I., Đurić, Z. G., Radulović, K.,& Frantlović, M.. (2017). Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer. in 2017 IEEE 30th International Conference on Microelectronics (MIEL)
IEEE., 127-130.
https://doi.org/10.1109/MIEL.2017.8190084
https://hdl.handle.net/21.15107/rcub_dais_3684
Jokić I, Đurić ZG, Radulović K, Frantlović M. Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer. in 2017 IEEE 30th International Conference on Microelectronics (MIEL). 2017;:127-130.
doi:10.1109/MIEL.2017.8190084
https://hdl.handle.net/21.15107/rcub_dais_3684 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, "Stochastic time response of adsorption-based micro/nanobiosensors with a fluidic reaction chamber: The influence of mass transfer" in 2017 IEEE 30th International Conference on Microelectronics (MIEL) (2017):127-130,
https://doi.org/10.1109/MIEL.2017.8190084 .,
https://hdl.handle.net/21.15107/rcub_dais_3684 .
1
1

Facile synthesis of hydrophilic polymer-capped upconverting NaYF4:Yb,Er particles

Dinić, Ivana; Mančić, Lidija; Nikolić, Marko G.; Radulović, Katarina; Marinković, Bojan A.; Milošević, Olivera

(Belgrade : Serbian Ceramic Society, 2017)

TY  - CONF
AU  - Dinić, Ivana
AU  - Mančić, Lidija
AU  - Nikolić, Marko G.
AU  - Radulović, Katarina
AU  - Marinković, Bojan A.
AU  - Milošević, Olivera
PY  - 2017
UR  - https://dais.sanu.ac.rs/123456789/2361
AB  - Over the last decade, solvothermal decomposition of organometallic compounds has been indicated as one of the most convenient method for the synthesis of monodisperse lanthanide doped upconverting fluorides. Due to their hydrophobic nature such particles could not be used for a conjugation of the molecular targeting agents which is necessary for optical imaging of biological tissues. In this work, hydrophilic NaYF4:Yb,Er (17 mol% Yb; 3mol% Er) nanoparticles were synthesized by facile one-pot hydrothermal synthesis performed with a help of chitosan (CS) and poly(acrylic acid) (PAA). Obtained powders were analyzed by X-ray powder diffraction (XRPD), field emission scanning electron microscopy (FESEM), Fourier transform infrared (FTIR) and photoluminescence (PL) spectroscopy. The obtained results implied that particle size, shape and surface characteristics are dependent on the polymer choice. Although both powders crystallize in the same crystal arrangement (cubic, Fm-3m) more intense red emission, assigned to the Er3+ 4F9/2 → 4I15/2 electronic transitions, characterize spherical NaYF4:Yb,Er@CS particles. To asses a biological safety of their use, viability of the human gingival fibroblasts (HFG) was additionally tested by a colorimetric MTT assay.
PB  - Belgrade : Serbian Ceramic Society
C3  - Program and the Book of Abstracts / Serbian Ceramic Society Conference Advanced Ceramics and Application VI: New Frontiers in Multifunctional Material Science and Processing, Serbia, Belgrade, September 18-20, 2017
T1  - Facile synthesis of hydrophilic polymer-capped upconverting NaYF4:Yb,Er particles
SP  - 67
EP  - 67
UR  - https://hdl.handle.net/21.15107/rcub_dais_2361
ER  - 
@conference{
author = "Dinić, Ivana and Mančić, Lidija and Nikolić, Marko G. and Radulović, Katarina and Marinković, Bojan A. and Milošević, Olivera",
year = "2017",
abstract = "Over the last decade, solvothermal decomposition of organometallic compounds has been indicated as one of the most convenient method for the synthesis of monodisperse lanthanide doped upconverting fluorides. Due to their hydrophobic nature such particles could not be used for a conjugation of the molecular targeting agents which is necessary for optical imaging of biological tissues. In this work, hydrophilic NaYF4:Yb,Er (17 mol% Yb; 3mol% Er) nanoparticles were synthesized by facile one-pot hydrothermal synthesis performed with a help of chitosan (CS) and poly(acrylic acid) (PAA). Obtained powders were analyzed by X-ray powder diffraction (XRPD), field emission scanning electron microscopy (FESEM), Fourier transform infrared (FTIR) and photoluminescence (PL) spectroscopy. The obtained results implied that particle size, shape and surface characteristics are dependent on the polymer choice. Although both powders crystallize in the same crystal arrangement (cubic, Fm-3m) more intense red emission, assigned to the Er3+ 4F9/2 → 4I15/2 electronic transitions, characterize spherical NaYF4:Yb,Er@CS particles. To asses a biological safety of their use, viability of the human gingival fibroblasts (HFG) was additionally tested by a colorimetric MTT assay.",
publisher = "Belgrade : Serbian Ceramic Society",
journal = "Program and the Book of Abstracts / Serbian Ceramic Society Conference Advanced Ceramics and Application VI: New Frontiers in Multifunctional Material Science and Processing, Serbia, Belgrade, September 18-20, 2017",
title = "Facile synthesis of hydrophilic polymer-capped upconverting NaYF4:Yb,Er particles",
pages = "67-67",
url = "https://hdl.handle.net/21.15107/rcub_dais_2361"
}
Dinić, I., Mančić, L., Nikolić, M. G., Radulović, K., Marinković, B. A.,& Milošević, O.. (2017). Facile synthesis of hydrophilic polymer-capped upconverting NaYF4:Yb,Er particles. in Program and the Book of Abstracts / Serbian Ceramic Society Conference Advanced Ceramics and Application VI: New Frontiers in Multifunctional Material Science and Processing, Serbia, Belgrade, September 18-20, 2017
Belgrade : Serbian Ceramic Society., 67-67.
https://hdl.handle.net/21.15107/rcub_dais_2361
Dinić I, Mančić L, Nikolić MG, Radulović K, Marinković BA, Milošević O. Facile synthesis of hydrophilic polymer-capped upconverting NaYF4:Yb,Er particles. in Program and the Book of Abstracts / Serbian Ceramic Society Conference Advanced Ceramics and Application VI: New Frontiers in Multifunctional Material Science and Processing, Serbia, Belgrade, September 18-20, 2017. 2017;:67-67.
https://hdl.handle.net/21.15107/rcub_dais_2361 .
Dinić, Ivana, Mančić, Lidija, Nikolić, Marko G., Radulović, Katarina, Marinković, Bojan A., Milošević, Olivera, "Facile synthesis of hydrophilic polymer-capped upconverting NaYF4:Yb,Er particles" in Program and the Book of Abstracts / Serbian Ceramic Society Conference Advanced Ceramics and Application VI: New Frontiers in Multifunctional Material Science and Processing, Serbia, Belgrade, September 18-20, 2017 (2017):67-67,
https://hdl.handle.net/21.15107/rcub_dais_2361 .

Fluctuations of the number of adsorbed micro/nanoparticles in sensors for measurement of particle concentration in air and liquid environments

Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina; Frantlović, Miloš

(Belgrade: Association of the Chemical Engineers of Serbia, 2015)

TY  - JOUR
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Frantlović, Miloš
PY  - 2015
UR  - https://dais.sanu.ac.rs/123456789/3538
AB  - A theoretical model of fluctuations of the number of adsorbed micro/nanoparticles in environmental sensors operating in air and liquids is presented, taking into account the effects of the mass transfer processes of the target particles in a sensor reaction chamber. The expressions for the total power of the corresponding adsorption-desorption noise, and for the corresponding signal-to-noise ratio are also derived. The presented analysis shows that the transfer processes can have a significant influence on the sensors limiting performance. The influence on both the fluctuations spectrum and the signal-to-noise ratio is estimated at different values of target particles concentration, functionalization sites surface density, and adsorption and desorption rate constants (the values are chosen from the ranges corresponding to real conditions). The analysis provides the guidelines for optimization of sensor design and operating conditions for the given target substance and sensor functionalization, in order to decrease the influence of the mass transfer, thus improving the ultimate performance (e.g., minimal detectable signal, signal-to-noise ratio) of sensors for particle detection. The calculations we performed show that it is possible to increase the signal-to-noise ratio for as much as two orders of magnitude by using optimization that eliminates the mass transfer influence. © 2015, CI and CEQ. All Rights Reserved.
PB  - Belgrade: Association of the Chemical Engineers of Serbia
T2  - Chemical Industry and Chemical Engineering Quarterly
T1  - Fluctuations of the number of adsorbed micro/nanoparticles in sensors for measurement of particle concentration in air and liquid environments
SP  - 141
EP  - 147
VL  - 21
IS  - 1-2
DO  - 10.2298/CICEQ140219011J
UR  - https://hdl.handle.net/21.15107/rcub_dais_3538
ER  - 
@article{
author = "Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina and Frantlović, Miloš",
year = "2015",
abstract = "A theoretical model of fluctuations of the number of adsorbed micro/nanoparticles in environmental sensors operating in air and liquids is presented, taking into account the effects of the mass transfer processes of the target particles in a sensor reaction chamber. The expressions for the total power of the corresponding adsorption-desorption noise, and for the corresponding signal-to-noise ratio are also derived. The presented analysis shows that the transfer processes can have a significant influence on the sensors limiting performance. The influence on both the fluctuations spectrum and the signal-to-noise ratio is estimated at different values of target particles concentration, functionalization sites surface density, and adsorption and desorption rate constants (the values are chosen from the ranges corresponding to real conditions). The analysis provides the guidelines for optimization of sensor design and operating conditions for the given target substance and sensor functionalization, in order to decrease the influence of the mass transfer, thus improving the ultimate performance (e.g., minimal detectable signal, signal-to-noise ratio) of sensors for particle detection. The calculations we performed show that it is possible to increase the signal-to-noise ratio for as much as two orders of magnitude by using optimization that eliminates the mass transfer influence. © 2015, CI and CEQ. All Rights Reserved.",
publisher = "Belgrade: Association of the Chemical Engineers of Serbia",
journal = "Chemical Industry and Chemical Engineering Quarterly",
title = "Fluctuations of the number of adsorbed micro/nanoparticles in sensors for measurement of particle concentration in air and liquid environments",
pages = "141-147",
volume = "21",
number = "1-2",
doi = "10.2298/CICEQ140219011J",
url = "https://hdl.handle.net/21.15107/rcub_dais_3538"
}
Jokić, I., Đurić, Z. G., Radulović, K.,& Frantlović, M.. (2015). Fluctuations of the number of adsorbed micro/nanoparticles in sensors for measurement of particle concentration in air and liquid environments. in Chemical Industry and Chemical Engineering Quarterly
Belgrade: Association of the Chemical Engineers of Serbia., 21(1-2), 141-147.
https://doi.org/10.2298/CICEQ140219011J
https://hdl.handle.net/21.15107/rcub_dais_3538
Jokić I, Đurić ZG, Radulović K, Frantlović M. Fluctuations of the number of adsorbed micro/nanoparticles in sensors for measurement of particle concentration in air and liquid environments. in Chemical Industry and Chemical Engineering Quarterly. 2015;21(1-2):141-147.
doi:10.2298/CICEQ140219011J
https://hdl.handle.net/21.15107/rcub_dais_3538 .
Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, Frantlović, Miloš, "Fluctuations of the number of adsorbed micro/nanoparticles in sensors for measurement of particle concentration in air and liquid environments" in Chemical Industry and Chemical Engineering Quarterly, 21, no. 1-2 (2015):141-147,
https://doi.org/10.2298/CICEQ140219011J .,
https://hdl.handle.net/21.15107/rcub_dais_3538 .
1
1
1

Adsorption-desorption noise in microfluidic biosensors operating in multianalyte environments

Jokić, Ivana; Frantlović, Miloš; Đurić, Zoran G.; Radulović, Katarina; Jokić, Zorana

(Elsevier, 2015)

TY  - JOUR
AU  - Jokić, Ivana
AU  - Frantlović, Miloš
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Jokić, Zorana
PY  - 2015
UR  - https://dais.sanu.ac.rs/123456789/3519
AB  - We present a theoretical model of adsorption-desorption (AD) noise in microfluidic biosensors operating in multianalyte environments. This noise is caused by the stochastic nature of the processes that generate the sensor response: reversible adsorption of n analytes coupled with mass transfer (convection and diffusion) of analyte particles through the microfluidic channel to and from the surface binding sites. The parameters of the obtained analytical expression for the AD noise power spectral density, determining the shape of the noise spectrum, contain information on the concentrations of all the adsorbing species, their association and dissociation rate constants, mass transfer coefficients and molecular masses. The AD noise spectrum, therefore, offers additional data about multiple analytes, apart from those obtained by the commonly used time domain analysis of sensor response. Therefore the derived model of AD noise contributes to the theoretical basis necessary for the development of new methods for determination of target analyte parameters in complex samples or even for simultaneous detection of multiple analytes using a single sensor, based on the measured noise spectrum. © 2015 Published by Elsevier B.V.
PB  - Elsevier
T2  - Microelectronic Engineering
T1  - Adsorption-desorption noise in microfluidic biosensors operating in multianalyte environments
SP  - 32
EP  - 36
VL  - 144
DO  - 10.1016/j.mee.2015.02.032
UR  - https://hdl.handle.net/21.15107/rcub_dais_3519
ER  - 
@article{
author = "Jokić, Ivana and Frantlović, Miloš and Đurić, Zoran G. and Radulović, Katarina and Jokić, Zorana",
year = "2015",
abstract = "We present a theoretical model of adsorption-desorption (AD) noise in microfluidic biosensors operating in multianalyte environments. This noise is caused by the stochastic nature of the processes that generate the sensor response: reversible adsorption of n analytes coupled with mass transfer (convection and diffusion) of analyte particles through the microfluidic channel to and from the surface binding sites. The parameters of the obtained analytical expression for the AD noise power spectral density, determining the shape of the noise spectrum, contain information on the concentrations of all the adsorbing species, their association and dissociation rate constants, mass transfer coefficients and molecular masses. The AD noise spectrum, therefore, offers additional data about multiple analytes, apart from those obtained by the commonly used time domain analysis of sensor response. Therefore the derived model of AD noise contributes to the theoretical basis necessary for the development of new methods for determination of target analyte parameters in complex samples or even for simultaneous detection of multiple analytes using a single sensor, based on the measured noise spectrum. © 2015 Published by Elsevier B.V.",
publisher = "Elsevier",
journal = "Microelectronic Engineering",
title = "Adsorption-desorption noise in microfluidic biosensors operating in multianalyte environments",
pages = "32-36",
volume = "144",
doi = "10.1016/j.mee.2015.02.032",
url = "https://hdl.handle.net/21.15107/rcub_dais_3519"
}
Jokić, I., Frantlović, M., Đurić, Z. G., Radulović, K.,& Jokić, Z.. (2015). Adsorption-desorption noise in microfluidic biosensors operating in multianalyte environments. in Microelectronic Engineering
Elsevier., 144, 32-36.
https://doi.org/10.1016/j.mee.2015.02.032
https://hdl.handle.net/21.15107/rcub_dais_3519
Jokić I, Frantlović M, Đurić ZG, Radulović K, Jokić Z. Adsorption-desorption noise in microfluidic biosensors operating in multianalyte environments. in Microelectronic Engineering. 2015;144:32-36.
doi:10.1016/j.mee.2015.02.032
https://hdl.handle.net/21.15107/rcub_dais_3519 .
Jokić, Ivana, Frantlović, Miloš, Đurić, Zoran G., Radulović, Katarina, Jokić, Zorana, "Adsorption-desorption noise in microfluidic biosensors operating in multianalyte environments" in Microelectronic Engineering, 144 (2015):32-36,
https://doi.org/10.1016/j.mee.2015.02.032 .,
https://hdl.handle.net/21.15107/rcub_dais_3519 .
1
12
9
11

Modelling the size separation of NdFeB magnetic microparticles by magnetophoresis and gravity settling

Radulović, Katarina; Radovanović, Filip; Ranđelović, Danijela; Jović, Vesna; Lamovec, Jelena; Vasiljević Radović, Dana; Jakšić, Zoran

(Belgrade : ETRAN Society, 2015)

TY  - CONF
AU  - Radulović, Katarina
AU  - Radovanović, Filip
AU  - Ranđelović, Danijela
AU  - Jović, Vesna
AU  - Lamovec, Jelena
AU  - Vasiljević Radović, Dana
AU  - Jakšić, Zoran
PY  - 2015
UR  - https://dais.sanu.ac.rs/123456789/787
AB  - Properties of sintered NdFeB magnets strongly depend on granulation and size distribution of constituent particles, which requires an efficient method for their separation into relatively narrow size fractions. We investigated two methods of magnetic particle separation from a mixture with different sizes using simulation by finite element method: magnetophoresis and gravity settling. In the case of magnetophoresis magnetic particles ranging in diameter from 1 to 10 m were deflected from the direction of continuous laminar flow by a perpendicular magnetic field. Larger particles were deflected from the direction of laminar flow more than smaller particles. The applied flow rate and strength and gradient of the applied magnetic field were the key parameters in controlling the deflection. The gravity settling model simulated spherical particles falling in heptane. Particles of various sizes were divided according to the time they needed to reach the bottom. The model used an axially symmetric fluid-flow simulation in a moving coordinate system connected with the particle, coupled with an ordinary differential equation for the force balance of the particle (gravity and drag force). The grain accelerated from standstill and rapidly reached its terminal velocity. This velocity was approximately proportional to the square of the particle radius, which led to clear separation of 5-10 um particles from those with a diameter of 1 um.
PB  - Belgrade : ETRAN Society
C3  - 59. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 8-11. juna, 2015. godine [i] 2nd International Conference on Electrical, Electronic and Computing Engineering IcETRAN 2015 Silver Lake (Srebrno jezero), Serbia, June 8-11, 2015: Proceedings
T1  - Modelling the size separation of NdFeB magnetic microparticles by magnetophoresis and gravity settling
UR  - https://hdl.handle.net/21.15107/rcub_dais_787
ER  - 
@conference{
author = "Radulović, Katarina and Radovanović, Filip and Ranđelović, Danijela and Jović, Vesna and Lamovec, Jelena and Vasiljević Radović, Dana and Jakšić, Zoran",
year = "2015",
abstract = "Properties of sintered NdFeB magnets strongly depend on granulation and size distribution of constituent particles, which requires an efficient method for their separation into relatively narrow size fractions. We investigated two methods of magnetic particle separation from a mixture with different sizes using simulation by finite element method: magnetophoresis and gravity settling. In the case of magnetophoresis magnetic particles ranging in diameter from 1 to 10 m were deflected from the direction of continuous laminar flow by a perpendicular magnetic field. Larger particles were deflected from the direction of laminar flow more than smaller particles. The applied flow rate and strength and gradient of the applied magnetic field were the key parameters in controlling the deflection. The gravity settling model simulated spherical particles falling in heptane. Particles of various sizes were divided according to the time they needed to reach the bottom. The model used an axially symmetric fluid-flow simulation in a moving coordinate system connected with the particle, coupled with an ordinary differential equation for the force balance of the particle (gravity and drag force). The grain accelerated from standstill and rapidly reached its terminal velocity. This velocity was approximately proportional to the square of the particle radius, which led to clear separation of 5-10 um particles from those with a diameter of 1 um.",
publisher = "Belgrade : ETRAN Society",
journal = "59. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 8-11. juna, 2015. godine [i] 2nd International Conference on Electrical, Electronic and Computing Engineering IcETRAN 2015 Silver Lake (Srebrno jezero), Serbia, June 8-11, 2015: Proceedings",
title = "Modelling the size separation of NdFeB magnetic microparticles by magnetophoresis and gravity settling",
url = "https://hdl.handle.net/21.15107/rcub_dais_787"
}
Radulović, K., Radovanović, F., Ranđelović, D., Jović, V., Lamovec, J., Vasiljević Radović, D.,& Jakšić, Z.. (2015). Modelling the size separation of NdFeB magnetic microparticles by magnetophoresis and gravity settling. in 59. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 8-11. juna, 2015. godine [i] 2nd International Conference on Electrical, Electronic and Computing Engineering IcETRAN 2015 Silver Lake (Srebrno jezero), Serbia, June 8-11, 2015: Proceedings
Belgrade : ETRAN Society..
https://hdl.handle.net/21.15107/rcub_dais_787
Radulović K, Radovanović F, Ranđelović D, Jović V, Lamovec J, Vasiljević Radović D, Jakšić Z. Modelling the size separation of NdFeB magnetic microparticles by magnetophoresis and gravity settling. in 59. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 8-11. juna, 2015. godine [i] 2nd International Conference on Electrical, Electronic and Computing Engineering IcETRAN 2015 Silver Lake (Srebrno jezero), Serbia, June 8-11, 2015: Proceedings. 2015;.
https://hdl.handle.net/21.15107/rcub_dais_787 .
Radulović, Katarina, Radovanović, Filip, Ranđelović, Danijela, Jović, Vesna, Lamovec, Jelena, Vasiljević Radović, Dana, Jakšić, Zoran, "Modelling the size separation of NdFeB magnetic microparticles by magnetophoresis and gravity settling" in 59. Konferencija za elektroniku, telekomunikacije, računarstvo, automatiku i nuklearnu tehniku, Srebrno jezero, 8-11. juna, 2015. godine [i] 2nd International Conference on Electrical, Electronic and Computing Engineering IcETRAN 2015 Silver Lake (Srebrno jezero), Serbia, June 8-11, 2015: Proceedings (2015),
https://hdl.handle.net/21.15107/rcub_dais_787 .

Preparation of NdFeB Magnetic Nanoparticles by Surfactant-Assisted High Energy Ball Milling

Lamovec, Jelena; Jović, Vesna; Radovanović, Filip; Ranđelović, Danijela; Radulović, Katarina; Jakšić, Zoran; Vasiljević Radović, Dana

(Belgrade : Materials Research Society of Serbia, 2015)

TY  - CONF
AU  - Lamovec, Jelena
AU  - Jović, Vesna
AU  - Radovanović, Filip
AU  - Ranđelović, Danijela
AU  - Radulović, Katarina
AU  - Jakšić, Zoran
AU  - Vasiljević Radović, Dana
PY  - 2015
UR  - https://dais.sanu.ac.rs/123456789/804
AB  - Improved permanent magnets are essential for emergent applications in electronic and electric devices. Different attempts have been made to produce nanoscale anisotropic rare-earth magnetic powder based on Nd-Fe-B material. Recently, high energy surfactant assisted ball milling has been proven to be an effective technique to produce anisotropic hard magnetic Nd-Fe-B nanoparticles. In this paper we are presenting our experimental results on high energy ball milling in planetary mill "Puverisette 7 premium line" from "Fritsch". Except milling material, there are several variables which influence the milling process for the selected mill type. They are: mechanical properties of the milling media material (bowls, balls, etc.), ball-to-powder ratio (BPR), extent of filling of the milling bowl, milling atmosphere, milling speed and duration, and type of solution and surfactant for wet milling. We are going to give influence of all these parameters on obtained NdFeB magnetic materials with nanosized dimensions starting from Nd2Fe14B HDD (Hydrogenated Disproportionated Desorbed) material. 

Acknowledgements: This work is funded by FP7 project MAG-DRIVE: "New permanent magnets for electric-vehicle drive applications", grant agreement no: 605348.
PB  - Belgrade : Materials Research Society of Serbia
C3  - Seventeenth Annual Conference YUCOMAT 2015, Aug 31-Sep 04, 2015, Herceg Novi, Montenegro, Programme and the Book of Abstracts
T1  - Preparation of NdFeB Magnetic Nanoparticles by Surfactant-Assisted High Energy Ball Milling
SP  - 66
EP  - 66
UR  - https://hdl.handle.net/21.15107/rcub_dais_804
ER  - 
@conference{
author = "Lamovec, Jelena and Jović, Vesna and Radovanović, Filip and Ranđelović, Danijela and Radulović, Katarina and Jakšić, Zoran and Vasiljević Radović, Dana",
year = "2015",
abstract = "Improved permanent magnets are essential for emergent applications in electronic and electric devices. Different attempts have been made to produce nanoscale anisotropic rare-earth magnetic powder based on Nd-Fe-B material. Recently, high energy surfactant assisted ball milling has been proven to be an effective technique to produce anisotropic hard magnetic Nd-Fe-B nanoparticles. In this paper we are presenting our experimental results on high energy ball milling in planetary mill "Puverisette 7 premium line" from "Fritsch". Except milling material, there are several variables which influence the milling process for the selected mill type. They are: mechanical properties of the milling media material (bowls, balls, etc.), ball-to-powder ratio (BPR), extent of filling of the milling bowl, milling atmosphere, milling speed and duration, and type of solution and surfactant for wet milling. We are going to give influence of all these parameters on obtained NdFeB magnetic materials with nanosized dimensions starting from Nd2Fe14B HDD (Hydrogenated Disproportionated Desorbed) material. 

Acknowledgements: This work is funded by FP7 project MAG-DRIVE: "New permanent magnets for electric-vehicle drive applications", grant agreement no: 605348.",
publisher = "Belgrade : Materials Research Society of Serbia",
journal = "Seventeenth Annual Conference YUCOMAT 2015, Aug 31-Sep 04, 2015, Herceg Novi, Montenegro, Programme and the Book of Abstracts",
title = "Preparation of NdFeB Magnetic Nanoparticles by Surfactant-Assisted High Energy Ball Milling",
pages = "66-66",
url = "https://hdl.handle.net/21.15107/rcub_dais_804"
}
Lamovec, J., Jović, V., Radovanović, F., Ranđelović, D., Radulović, K., Jakšić, Z.,& Vasiljević Radović, D.. (2015). Preparation of NdFeB Magnetic Nanoparticles by Surfactant-Assisted High Energy Ball Milling. in Seventeenth Annual Conference YUCOMAT 2015, Aug 31-Sep 04, 2015, Herceg Novi, Montenegro, Programme and the Book of Abstracts
Belgrade : Materials Research Society of Serbia., 66-66.
https://hdl.handle.net/21.15107/rcub_dais_804
Lamovec J, Jović V, Radovanović F, Ranđelović D, Radulović K, Jakšić Z, Vasiljević Radović D. Preparation of NdFeB Magnetic Nanoparticles by Surfactant-Assisted High Energy Ball Milling. in Seventeenth Annual Conference YUCOMAT 2015, Aug 31-Sep 04, 2015, Herceg Novi, Montenegro, Programme and the Book of Abstracts. 2015;:66-66.
https://hdl.handle.net/21.15107/rcub_dais_804 .
Lamovec, Jelena, Jović, Vesna, Radovanović, Filip, Ranđelović, Danijela, Radulović, Katarina, Jakšić, Zoran, Vasiljević Radović, Dana, "Preparation of NdFeB Magnetic Nanoparticles by Surfactant-Assisted High Energy Ball Milling" in Seventeenth Annual Conference YUCOMAT 2015, Aug 31-Sep 04, 2015, Herceg Novi, Montenegro, Programme and the Book of Abstracts (2015):66-66,
https://hdl.handle.net/21.15107/rcub_dais_804 .

Resonant Frequency and Phase Noise of Nanoelectromechanical Oscillators Based on Two-dimensional Crystal Resonators

Đurić, Zoran G.; Jokić, Ivana; Radulović, Katarina

(Elsevier, 2014)

TY  - JOUR
AU  - Đurić, Zoran G.
AU  - Jokić, Ivana
AU  - Radulović, Katarina
PY  - 2014
UR  - https://dais.sanu.ac.rs/123456789/644
AB  - This study presents a theoretical analysis of one of the most promising nanoelectromechanical (NEMS) components – a NEMS oscillator. The analyzed oscillator contains a stretched circular plate, fabricated of two-dimensional crystals (graphene, bBN, MoS2 etc.), as a resonator. The calculation of resonant frequency based on the classical continuum theory of plates and membranes is presented, and then the phase noise theory of the oscillators using a circular plate as a frequency determining element. We assume that thermal and 1/f noise are present in the oscillator circuit. A satisfactory agreement is obtained between our calculations and recent experimental literature data for graphene.
PB  - Elsevier
T2  - Procedia Engineering
T1  - Resonant Frequency and Phase Noise of Nanoelectromechanical Oscillators Based on Two-dimensional Crystal Resonators
SP  - 460
EP  - 463
VL  - 87
DO  - 10.1016/j.proeng.2014.11.382
UR  - https://hdl.handle.net/21.15107/rcub_dais_644
ER  - 
@article{
author = "Đurić, Zoran G. and Jokić, Ivana and Radulović, Katarina",
year = "2014",
abstract = "This study presents a theoretical analysis of one of the most promising nanoelectromechanical (NEMS) components – a NEMS oscillator. The analyzed oscillator contains a stretched circular plate, fabricated of two-dimensional crystals (graphene, bBN, MoS2 etc.), as a resonator. The calculation of resonant frequency based on the classical continuum theory of plates and membranes is presented, and then the phase noise theory of the oscillators using a circular plate as a frequency determining element. We assume that thermal and 1/f noise are present in the oscillator circuit. A satisfactory agreement is obtained between our calculations and recent experimental literature data for graphene.",
publisher = "Elsevier",
journal = "Procedia Engineering",
title = "Resonant Frequency and Phase Noise of Nanoelectromechanical Oscillators Based on Two-dimensional Crystal Resonators",
pages = "460-463",
volume = "87",
doi = "10.1016/j.proeng.2014.11.382",
url = "https://hdl.handle.net/21.15107/rcub_dais_644"
}
Đurić, Z. G., Jokić, I.,& Radulović, K.. (2014). Resonant Frequency and Phase Noise of Nanoelectromechanical Oscillators Based on Two-dimensional Crystal Resonators. in Procedia Engineering
Elsevier., 87, 460-463.
https://doi.org/10.1016/j.proeng.2014.11.382
https://hdl.handle.net/21.15107/rcub_dais_644
Đurić ZG, Jokić I, Radulović K. Resonant Frequency and Phase Noise of Nanoelectromechanical Oscillators Based on Two-dimensional Crystal Resonators. in Procedia Engineering. 2014;87:460-463.
doi:10.1016/j.proeng.2014.11.382
https://hdl.handle.net/21.15107/rcub_dais_644 .
Đurić, Zoran G., Jokić, Ivana, Radulović, Katarina, "Resonant Frequency and Phase Noise of Nanoelectromechanical Oscillators Based on Two-dimensional Crystal Resonators" in Procedia Engineering, 87 (2014):460-463,
https://doi.org/10.1016/j.proeng.2014.11.382 .,
https://hdl.handle.net/21.15107/rcub_dais_644 .
2
2
2

Numerical simulation of transient response of chemical and biological micro/nanofabricated sensors operating in multianalyte environments

Radulović, Katarina; Jokić, Ivana; Frantlović, Miloš; Đurić, Zoran G.

(IEEE, 2014)

TY  - CONF
AU  - Radulović, Katarina
AU  - Jokić, Ivana
AU  - Frantlović, Miloš
AU  - Đurić, Zoran G.
PY  - 2014
UR  - https://dais.sanu.ac.rs/123456789/649
AB  - In different kinds of surface-based chemical and biological micro/nanosensors, interpretation of the experimentally obtained data is performed based on approximate solutions for the sensor response, valid for the case of single-analyte samples. A question arises whether or not the approximate models used for experimental data fitting in the case of a single analyte are also applicable for multianalyte environments. We test the validity of the two-compartment model for approximation of sensor transient response in the case of concurrent binding of multiple analytes on the sensing surface, by comparing the approximate response with the numerical simulation of the dynamics of a real adsorption experiment.
PB  - IEEE
C3  - Proceedings of the International Conference on Microelectronics, ICM (2014 29th International Conference on Microelectronics, MIEL 2014)
T1  - Numerical simulation of transient response of chemical and biological micro/nanofabricated sensors operating in multianalyte environments
SP  - 187
EP  - 190
UR  - https://hdl.handle.net/21.15107/rcub_dais_649
ER  - 
@conference{
author = "Radulović, Katarina and Jokić, Ivana and Frantlović, Miloš and Đurić, Zoran G.",
year = "2014",
abstract = "In different kinds of surface-based chemical and biological micro/nanosensors, interpretation of the experimentally obtained data is performed based on approximate solutions for the sensor response, valid for the case of single-analyte samples. A question arises whether or not the approximate models used for experimental data fitting in the case of a single analyte are also applicable for multianalyte environments. We test the validity of the two-compartment model for approximation of sensor transient response in the case of concurrent binding of multiple analytes on the sensing surface, by comparing the approximate response with the numerical simulation of the dynamics of a real adsorption experiment.",
publisher = "IEEE",
journal = "Proceedings of the International Conference on Microelectronics, ICM (2014 29th International Conference on Microelectronics, MIEL 2014)",
title = "Numerical simulation of transient response of chemical and biological micro/nanofabricated sensors operating in multianalyte environments",
pages = "187-190",
url = "https://hdl.handle.net/21.15107/rcub_dais_649"
}
Radulović, K., Jokić, I., Frantlović, M.,& Đurić, Z. G.. (2014). Numerical simulation of transient response of chemical and biological micro/nanofabricated sensors operating in multianalyte environments. in Proceedings of the International Conference on Microelectronics, ICM (2014 29th International Conference on Microelectronics, MIEL 2014)
IEEE., 187-190.
https://hdl.handle.net/21.15107/rcub_dais_649
Radulović K, Jokić I, Frantlović M, Đurić ZG. Numerical simulation of transient response of chemical and biological micro/nanofabricated sensors operating in multianalyte environments. in Proceedings of the International Conference on Microelectronics, ICM (2014 29th International Conference on Microelectronics, MIEL 2014). 2014;:187-190.
https://hdl.handle.net/21.15107/rcub_dais_649 .
Radulović, Katarina, Jokić, Ivana, Frantlović, Miloš, Đurić, Zoran G., "Numerical simulation of transient response of chemical and biological micro/nanofabricated sensors operating in multianalyte environments" in Proceedings of the International Conference on Microelectronics, ICM (2014 29th International Conference on Microelectronics, MIEL 2014) (2014):187-190,
https://hdl.handle.net/21.15107/rcub_dais_649 .

Analysis of the competitive adsorption and mass transfer influence on equilibrium mass fluctuations in affinity-based biosensors

Frantlović, Miloš; Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina

(Elsevier, 2013)

TY  - JOUR
AU  - Frantlović, Miloš
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
PY  - 2013
UR  - https://dais.sanu.ac.rs/123456789/350
AB  - We analyze the fluctuations of the equilibrium adsorbed mass in affinity-based biosensors, considering adsorption–desorption and mass transfer processes of two molecular species which compete for binding to the same probe molecules immobilized on the sensing surface. The analytical expression for the fluctuations spectral density is derived. The calculations show the significant influence of both the competitive adsorption and the mass transfer on the fluctuations spectrum, and also of their combined effect. The dependences of the fluctuations on association and dissociation rate constants of both adsorbing species, their concentrations, molecular masses and mass transfer coefficients and also on the density of capturing probes can be examined by using the presented model. The model is applicable for biosensors in which the spatial distribution of adsorbates concentrations in the reaction chamber can be approximated using the two-compartment model. The theory provides a more realistic estimation of the biosensors’ limiting performance, and is useful for their improvement.
PB  - Elsevier
T2  - Sensors and Actuators B: Chemical
T1  - Analysis of the competitive adsorption and mass transfer influence on equilibrium mass fluctuations in affinity-based biosensors
SP  - 71
EP  - 79
VL  - 189
DO  - 10.1016/j.snb.2012.12.080
UR  - https://hdl.handle.net/21.15107/rcub_dais_350
ER  - 
@article{
author = "Frantlović, Miloš and Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina",
year = "2013",
abstract = "We analyze the fluctuations of the equilibrium adsorbed mass in affinity-based biosensors, considering adsorption–desorption and mass transfer processes of two molecular species which compete for binding to the same probe molecules immobilized on the sensing surface. The analytical expression for the fluctuations spectral density is derived. The calculations show the significant influence of both the competitive adsorption and the mass transfer on the fluctuations spectrum, and also of their combined effect. The dependences of the fluctuations on association and dissociation rate constants of both adsorbing species, their concentrations, molecular masses and mass transfer coefficients and also on the density of capturing probes can be examined by using the presented model. The model is applicable for biosensors in which the spatial distribution of adsorbates concentrations in the reaction chamber can be approximated using the two-compartment model. The theory provides a more realistic estimation of the biosensors’ limiting performance, and is useful for their improvement.",
publisher = "Elsevier",
journal = "Sensors and Actuators B: Chemical",
title = "Analysis of the competitive adsorption and mass transfer influence on equilibrium mass fluctuations in affinity-based biosensors",
pages = "71-79",
volume = "189",
doi = "10.1016/j.snb.2012.12.080",
url = "https://hdl.handle.net/21.15107/rcub_dais_350"
}
Frantlović, M., Jokić, I., Đurić, Z. G.,& Radulović, K.. (2013). Analysis of the competitive adsorption and mass transfer influence on equilibrium mass fluctuations in affinity-based biosensors. in Sensors and Actuators B: Chemical
Elsevier., 189, 71-79.
https://doi.org/10.1016/j.snb.2012.12.080
https://hdl.handle.net/21.15107/rcub_dais_350
Frantlović M, Jokić I, Đurić ZG, Radulović K. Analysis of the competitive adsorption and mass transfer influence on equilibrium mass fluctuations in affinity-based biosensors. in Sensors and Actuators B: Chemical. 2013;189:71-79.
doi:10.1016/j.snb.2012.12.080
https://hdl.handle.net/21.15107/rcub_dais_350 .
Frantlović, Miloš, Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, "Analysis of the competitive adsorption and mass transfer influence on equilibrium mass fluctuations in affinity-based biosensors" in Sensors and Actuators B: Chemical, 189 (2013):71-79,
https://doi.org/10.1016/j.snb.2012.12.080 .,
https://hdl.handle.net/21.15107/rcub_dais_350 .
14
11
14

Analysis of the Influence of Competitive Adsorption and Mass Transfer on Adsorbed Mass Fluctuations in Affinity-Based Biosensors

Frantlović, Miloš; Jokić, Ivana; Đurić, Zoran G.; Radulović, Katarina

(Elsevier, 2012)

TY  - CONF
AU  - Frantlović, Miloš
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
PY  - 2012
UR  - https://dais.sanu.ac.rs/123456789/4839
AB  - We analyze the fluctuations of the equilibrium adsorbed mass in affinity-based biosensors, caused by both the random nature of adsorption-desorption and mass transfer processes of two molecular species (the target and the competitor molecules) which bind to the probe molecules. The analytical expression for the fluctuations spectral density is derived. The calculations show the significant influence of both the competitive adsorption and the mass transfer on the fluctuations spectrum. The theory provides a more realistic estimation of limiting performance of biosensors, and is useful for their improvement.
PB  - Elsevier
C3  - Procedia Engineering
T1  - Analysis of the Influence of Competitive Adsorption and Mass Transfer on Adsorbed Mass Fluctuations in Affinity-Based Biosensors
SP  - 957
EP  - 960
VL  - 47
DO  - 10.1016/j.proeng.2012.09.305
UR  - https://hdl.handle.net/21.15107/rcub_dais_4839
ER  - 
@conference{
author = "Frantlović, Miloš and Jokić, Ivana and Đurić, Zoran G. and Radulović, Katarina",
year = "2012",
abstract = "We analyze the fluctuations of the equilibrium adsorbed mass in affinity-based biosensors, caused by both the random nature of adsorption-desorption and mass transfer processes of two molecular species (the target and the competitor molecules) which bind to the probe molecules. The analytical expression for the fluctuations spectral density is derived. The calculations show the significant influence of both the competitive adsorption and the mass transfer on the fluctuations spectrum. The theory provides a more realistic estimation of limiting performance of biosensors, and is useful for their improvement.",
publisher = "Elsevier",
journal = "Procedia Engineering",
title = "Analysis of the Influence of Competitive Adsorption and Mass Transfer on Adsorbed Mass Fluctuations in Affinity-Based Biosensors",
pages = "957-960",
volume = "47",
doi = "10.1016/j.proeng.2012.09.305",
url = "https://hdl.handle.net/21.15107/rcub_dais_4839"
}
Frantlović, M., Jokić, I., Đurić, Z. G.,& Radulović, K.. (2012). Analysis of the Influence of Competitive Adsorption and Mass Transfer on Adsorbed Mass Fluctuations in Affinity-Based Biosensors. in Procedia Engineering
Elsevier., 47, 957-960.
https://doi.org/10.1016/j.proeng.2012.09.305
https://hdl.handle.net/21.15107/rcub_dais_4839
Frantlović M, Jokić I, Đurić ZG, Radulović K. Analysis of the Influence of Competitive Adsorption and Mass Transfer on Adsorbed Mass Fluctuations in Affinity-Based Biosensors. in Procedia Engineering. 2012;47:957-960.
doi:10.1016/j.proeng.2012.09.305
https://hdl.handle.net/21.15107/rcub_dais_4839 .
Frantlović, Miloš, Jokić, Ivana, Đurić, Zoran G., Radulović, Katarina, "Analysis of the Influence of Competitive Adsorption and Mass Transfer on Adsorbed Mass Fluctuations in Affinity-Based Biosensors" in Procedia Engineering, 47 (2012):957-960,
https://doi.org/10.1016/j.proeng.2012.09.305 .,
https://hdl.handle.net/21.15107/rcub_dais_4839 .
1

Intrinsic noise equivalent concentration of dynamic mode microcantilever biosensors

Đurić, Zoran G.; Jokić, Ivana; Frantlović, Miloš; Radulović, Katarina

(2012)

TY  - CONF
AU  - Đurić, Zoran G.
AU  - Jokić, Ivana
AU  - Frantlović, Miloš
AU  - Radulović, Katarina
PY  - 2012
UR  - https://dais.sanu.ac.rs/123456789/553
AB  - The presented theory enables systematic investigation of the dependence of the minimal detectable concentration of the target analyte, determined by the cantilever intrinsic noise, on various parameters. Inclusion of the influence of effects such as the mass transfer in noise considerations results in a more accurate noise model, which is necessary when methods based on noise measurements are developed.

Poster presented at the 38th International Conference on Micro and Nano Engineering MNE, 16-20 September 2012, Toulouse, France
T1  - Intrinsic noise equivalent concentration of dynamic mode microcantilever biosensors
UR  - https://hdl.handle.net/21.15107/rcub_dais_553
ER  - 
@conference{
author = "Đurić, Zoran G. and Jokić, Ivana and Frantlović, Miloš and Radulović, Katarina",
year = "2012",
abstract = "The presented theory enables systematic investigation of the dependence of the minimal detectable concentration of the target analyte, determined by the cantilever intrinsic noise, on various parameters. Inclusion of the influence of effects such as the mass transfer in noise considerations results in a more accurate noise model, which is necessary when methods based on noise measurements are developed.

Poster presented at the 38th International Conference on Micro and Nano Engineering MNE, 16-20 September 2012, Toulouse, France",
title = "Intrinsic noise equivalent concentration of dynamic mode microcantilever biosensors",
url = "https://hdl.handle.net/21.15107/rcub_dais_553"
}
Đurić, Z. G., Jokić, I., Frantlović, M.,& Radulović, K.. (2012). Intrinsic noise equivalent concentration of dynamic mode microcantilever biosensors. .
https://hdl.handle.net/21.15107/rcub_dais_553
Đurić ZG, Jokić I, Frantlović M, Radulović K. Intrinsic noise equivalent concentration of dynamic mode microcantilever biosensors. 2012;.
https://hdl.handle.net/21.15107/rcub_dais_553 .
Đurić, Zoran G., Jokić, Ivana, Frantlović, Miloš, Radulović, Katarina, "Intrinsic noise equivalent concentration of dynamic mode microcantilever biosensors" (2012),
https://hdl.handle.net/21.15107/rcub_dais_553 .

Fluctuations of the number of adsorbed molecules in biosensors due to stochastic adsorption–desorption processes coupled with mass transfer

Jokić, Ivana; Đurić, Zoran G.; Frantlović, Miloš; Radulović, Katarina; Krstajić, Predrag; Jokić, Zorana

(Elsevier, 2012)

TY  - JOUR
AU  - Jokić, Ivana
AU  - Đurić, Zoran G.
AU  - Frantlović, Miloš
AU  - Radulović, Katarina
AU  - Krstajić, Predrag
AU  - Jokić, Zorana
PY  - 2012
UR  - https://dais.sanu.ac.rs/123456789/470
AB  - We derived a simple theory of fluctuations of the equilibrium number of adsorbed molecules in biosensors, caused by the stochastic nature of adsorption–desorption (AD) processes coupled with mass transfer. The two-compartment model is used for approximation of the spatial dependence of analyte concentration in the reaction chamber, which is justified when a thin layer depleted of the analyte exists close to the surface on which the binding reaction occurs. By using the obtained analytical expression for the power spectral density of fluctuations we perform for the first time the quantitative analysis of the influence of the mass transfer on the fluctuations spectrum. For realistic parameter values, the influence of mass transfer proved to be significant, causing the increase in the fluctuations level of up to two orders of magnitude compared to the rapid mixing case. The dependences of the mass transfer influenced fluctuations spectrum on various parameters of the analyte–receptor binding process are also systematically investigated. The presented theoretical model of fluctuations enables good estimation of the AD noise, which affects the total noise and the minimal detectable signal of biosensors. It provides the guidelines for improvement of the limits of detection, and for optimization of detection methods. The theory is also proposed as a basis for development of highly sensitive methods for analyte detection and characterization of biomolecular binding processes, based on the measured fluctuations spectrum. It is applicable for various types of sensors whose operation principle relies on the adsorption process of analyte molecules.
PB  - Elsevier
T2  - Sensors and Actuators B: Chemical
T1  - Fluctuations of the number of adsorbed molecules in biosensors due to stochastic adsorption–desorption processes coupled with mass transfer
SP  - 535
EP  - 543
DO  - 10.1016/j.snb.2012.03.004
UR  - https://hdl.handle.net/21.15107/rcub_dais_470
ER  - 
@article{
author = "Jokić, Ivana and Đurić, Zoran G. and Frantlović, Miloš and Radulović, Katarina and Krstajić, Predrag and Jokić, Zorana",
year = "2012",
abstract = "We derived a simple theory of fluctuations of the equilibrium number of adsorbed molecules in biosensors, caused by the stochastic nature of adsorption–desorption (AD) processes coupled with mass transfer. The two-compartment model is used for approximation of the spatial dependence of analyte concentration in the reaction chamber, which is justified when a thin layer depleted of the analyte exists close to the surface on which the binding reaction occurs. By using the obtained analytical expression for the power spectral density of fluctuations we perform for the first time the quantitative analysis of the influence of the mass transfer on the fluctuations spectrum. For realistic parameter values, the influence of mass transfer proved to be significant, causing the increase in the fluctuations level of up to two orders of magnitude compared to the rapid mixing case. The dependences of the mass transfer influenced fluctuations spectrum on various parameters of the analyte–receptor binding process are also systematically investigated. The presented theoretical model of fluctuations enables good estimation of the AD noise, which affects the total noise and the minimal detectable signal of biosensors. It provides the guidelines for improvement of the limits of detection, and for optimization of detection methods. The theory is also proposed as a basis for development of highly sensitive methods for analyte detection and characterization of biomolecular binding processes, based on the measured fluctuations spectrum. It is applicable for various types of sensors whose operation principle relies on the adsorption process of analyte molecules.",
publisher = "Elsevier",
journal = "Sensors and Actuators B: Chemical",
title = "Fluctuations of the number of adsorbed molecules in biosensors due to stochastic adsorption–desorption processes coupled with mass transfer",
pages = "535-543",
doi = "10.1016/j.snb.2012.03.004",
url = "https://hdl.handle.net/21.15107/rcub_dais_470"
}
Jokić, I., Đurić, Z. G., Frantlović, M., Radulović, K., Krstajić, P.,& Jokić, Z.. (2012). Fluctuations of the number of adsorbed molecules in biosensors due to stochastic adsorption–desorption processes coupled with mass transfer. in Sensors and Actuators B: Chemical
Elsevier., 535-543.
https://doi.org/10.1016/j.snb.2012.03.004
https://hdl.handle.net/21.15107/rcub_dais_470
Jokić I, Đurić ZG, Frantlović M, Radulović K, Krstajić P, Jokić Z. Fluctuations of the number of adsorbed molecules in biosensors due to stochastic adsorption–desorption processes coupled with mass transfer. in Sensors and Actuators B: Chemical. 2012;:535-543.
doi:10.1016/j.snb.2012.03.004
https://hdl.handle.net/21.15107/rcub_dais_470 .
Jokić, Ivana, Đurić, Zoran G., Frantlović, Miloš, Radulović, Katarina, Krstajić, Predrag, Jokić, Zorana, "Fluctuations of the number of adsorbed molecules in biosensors due to stochastic adsorption–desorption processes coupled with mass transfer" in Sensors and Actuators B: Chemical (2012):535-543,
https://doi.org/10.1016/j.snb.2012.03.004 .,
https://hdl.handle.net/21.15107/rcub_dais_470 .
22
19
22

Adsorption–desorption noise in nanowire FET biosensors

Radulović, Katarina; Jokić, Ivana; Frantlović, Miloš; Đurić, Zoran G.

(IEEE, 2012)

TY  - CONF
AU  - Radulović, Katarina
AU  - Jokić, Ivana
AU  - Frantlović, Miloš
AU  - Đurić, Zoran G.
PY  - 2012
UR  - https://dais.sanu.ac.rs/123456789/450
AB  - The adsorption-desorption (AD) noise in nanowire FET biosensors is analyzed, which manifests itself in the form of gate voltage fluctuations resulting from the fluctuations of the number of adsorbed particles. The derived theoretical model of the fluctuations takes into account the mass transfer effects. The numerical calculations show that when the mass transfer is slow, the low-frequency amplitude and the corner frequency of the Lorentzian AD noise spectrum obtained by derived expressions are significantly different compared to the same parameters predicted by the model that neglects mass transport effects. The presented analysis enables good estimation of these parameters from the measured noise spectrum, which is important because they are used as the source of information about the analyte concentration and the kinetics of biomolecular interactions.
PB  - IEEE
C3  - 2012 28th International Conference on Microelectronics (MIEL)
T1  - Adsorption–desorption noise in nanowire FET biosensors
SP  - 203
EP  - 206
DO  - 10.1109/MIEL.2012.6222834
UR  - https://hdl.handle.net/21.15107/rcub_dais_450
ER  - 
@conference{
author = "Radulović, Katarina and Jokić, Ivana and Frantlović, Miloš and Đurić, Zoran G.",
year = "2012",
abstract = "The adsorption-desorption (AD) noise in nanowire FET biosensors is analyzed, which manifests itself in the form of gate voltage fluctuations resulting from the fluctuations of the number of adsorbed particles. The derived theoretical model of the fluctuations takes into account the mass transfer effects. The numerical calculations show that when the mass transfer is slow, the low-frequency amplitude and the corner frequency of the Lorentzian AD noise spectrum obtained by derived expressions are significantly different compared to the same parameters predicted by the model that neglects mass transport effects. The presented analysis enables good estimation of these parameters from the measured noise spectrum, which is important because they are used as the source of information about the analyte concentration and the kinetics of biomolecular interactions.",
publisher = "IEEE",
journal = "2012 28th International Conference on Microelectronics (MIEL)",
title = "Adsorption–desorption noise in nanowire FET biosensors",
pages = "203-206",
doi = "10.1109/MIEL.2012.6222834",
url = "https://hdl.handle.net/21.15107/rcub_dais_450"
}
Radulović, K., Jokić, I., Frantlović, M.,& Đurić, Z. G.. (2012). Adsorption–desorption noise in nanowire FET biosensors. in 2012 28th International Conference on Microelectronics (MIEL)
IEEE., 203-206.
https://doi.org/10.1109/MIEL.2012.6222834
https://hdl.handle.net/21.15107/rcub_dais_450
Radulović K, Jokić I, Frantlović M, Đurić ZG. Adsorption–desorption noise in nanowire FET biosensors. in 2012 28th International Conference on Microelectronics (MIEL). 2012;:203-206.
doi:10.1109/MIEL.2012.6222834
https://hdl.handle.net/21.15107/rcub_dais_450 .
Radulović, Katarina, Jokić, Ivana, Frantlović, Miloš, Đurić, Zoran G., "Adsorption–desorption noise in nanowire FET biosensors" in 2012 28th International Conference on Microelectronics (MIEL) (2012):203-206,
https://doi.org/10.1109/MIEL.2012.6222834 .,
https://hdl.handle.net/21.15107/rcub_dais_450 .
4
4

Characterization of adsorption-desorption processes on semiconductor surfaces using nanocantilever mass sensors

Đurić, Zoran G.; Radulović, Katarina; Jokić, Ivana; Frantlović, Miloš

(IEEE, 2012)

TY  - CONF
AU  - Đurić, Zoran G.
AU  - Radulović, Katarina
AU  - Jokić, Ivana
AU  - Frantlović, Miloš
PY  - 2012
UR  - https://dais.sanu.ac.rs/123456789/449
AB  - Characterization of adsorption-desorption (AD) processes of gas particles on semiconductors is necessary in order to investigate the influence of these processes on the micro/nano-devices performance. By applying a numerical computational method we determined the pressure dependence of the equilibrium coverage of the semiconductor surface by chemisorbed gas particles. We concluded that the pressure dependence of the total coverage of the surface by adparticles, and also of coverages by both the neutral and ionized adparticles, can be obtained by measuring the adsorbed mass. We propose the use of nanocantilever sensors for such extremely sensitive mass measurements. The obtained adsorption induced cantilever's resonant frequency shifts are higher than the detection threshold set by the termomechanical noise. This confirms the applicability of the used nanocantilever sensor for experimental characterization of AD processes at semiconductor surfaces.
PB  - IEEE
C3  - 2012 28th International Conference on Microelectronics (MIEL)
T1  - Characterization of adsorption-desorption processes on semiconductor surfaces using nanocantilever mass sensors
SP  - 161
EP  - 164
DO  - 10.1109/MIEL.2012.6222823
UR  - https://hdl.handle.net/21.15107/rcub_dais_449
ER  - 
@conference{
author = "Đurić, Zoran G. and Radulović, Katarina and Jokić, Ivana and Frantlović, Miloš",
year = "2012",
abstract = "Characterization of adsorption-desorption (AD) processes of gas particles on semiconductors is necessary in order to investigate the influence of these processes on the micro/nano-devices performance. By applying a numerical computational method we determined the pressure dependence of the equilibrium coverage of the semiconductor surface by chemisorbed gas particles. We concluded that the pressure dependence of the total coverage of the surface by adparticles, and also of coverages by both the neutral and ionized adparticles, can be obtained by measuring the adsorbed mass. We propose the use of nanocantilever sensors for such extremely sensitive mass measurements. The obtained adsorption induced cantilever's resonant frequency shifts are higher than the detection threshold set by the termomechanical noise. This confirms the applicability of the used nanocantilever sensor for experimental characterization of AD processes at semiconductor surfaces.",
publisher = "IEEE",
journal = "2012 28th International Conference on Microelectronics (MIEL)",
title = "Characterization of adsorption-desorption processes on semiconductor surfaces using nanocantilever mass sensors",
pages = "161-164",
doi = "10.1109/MIEL.2012.6222823",
url = "https://hdl.handle.net/21.15107/rcub_dais_449"
}
Đurić, Z. G., Radulović, K., Jokić, I.,& Frantlović, M.. (2012). Characterization of adsorption-desorption processes on semiconductor surfaces using nanocantilever mass sensors. in 2012 28th International Conference on Microelectronics (MIEL)
IEEE., 161-164.
https://doi.org/10.1109/MIEL.2012.6222823
https://hdl.handle.net/21.15107/rcub_dais_449
Đurić ZG, Radulović K, Jokić I, Frantlović M. Characterization of adsorption-desorption processes on semiconductor surfaces using nanocantilever mass sensors. in 2012 28th International Conference on Microelectronics (MIEL). 2012;:161-164.
doi:10.1109/MIEL.2012.6222823
https://hdl.handle.net/21.15107/rcub_dais_449 .
Đurić, Zoran G., Radulović, Katarina, Jokić, Ivana, Frantlović, Miloš, "Characterization of adsorption-desorption processes on semiconductor surfaces using nanocantilever mass sensors" in 2012 28th International Conference on Microelectronics (MIEL) (2012):161-164,
https://doi.org/10.1109/MIEL.2012.6222823 .,
https://hdl.handle.net/21.15107/rcub_dais_449 .

Segmented thermistors printed by NTC nanometric paste and applied in volume air-flow sensors

Aleksić, Obrad S.; Savić, Slavica; Luković, Miloljub D.; Radulović, Katarina; Lukić, Lazar S.

(2006)

TY  - CONF
AU  - Aleksić, Obrad S.
AU  - Savić, Slavica
AU  - Luković, Miloljub D.
AU  - Radulović, Katarina
AU  - Lukić, Lazar S.
PY  - 2006
UR  - https://dais.sanu.ac.rs/123456789/9556
AB  - An investigation path starting from (Mn,Ni,Co,Fe)3O4 nanometric powder preparation, NTC thick-film characterization, realization and optimization of new planar thermistor geometries to custom design thermistors and their application for temperature and volume airflow sensors was recently determined. The aim was to make custom designed segmented NTC thermistors printed and sintered on alumina. Two types of volume airflow sensors were formed: indirectly heated and self-heated. A pair of segmented thermistors was placed in an air guide and connected to differential branches of the Wheatstone bridge. A heater was placed in the middle between the thermistors for the indirectly heated type, while for the self-heated type the same thermistors were self-heated by a constant current source. First the thermistor responses vs. the airflow (calibration curves) were measured, and then thermistor responses in time (inertia) to fast airflow changes from the minimum to the maximum. The results obtained could be applied in air conditioning for air guide flow regulation.
C3  - Recent Developments in Advanced Materials and Processe
T1  - Segmented thermistors printed by NTC nanometric paste and applied in volume air-flow sensors
SP  - 247
EP  - 252
VL  - 518
DO  - 10.4028/www.scientific.net/MSF.518.247
UR  - https://hdl.handle.net/21.15107/rcub_dais_9556
ER  - 
@conference{
author = "Aleksić, Obrad S. and Savić, Slavica and Luković, Miloljub D. and Radulović, Katarina and Lukić, Lazar S.",
year = "2006",
abstract = "An investigation path starting from (Mn,Ni,Co,Fe)3O4 nanometric powder preparation, NTC thick-film characterization, realization and optimization of new planar thermistor geometries to custom design thermistors and their application for temperature and volume airflow sensors was recently determined. The aim was to make custom designed segmented NTC thermistors printed and sintered on alumina. Two types of volume airflow sensors were formed: indirectly heated and self-heated. A pair of segmented thermistors was placed in an air guide and connected to differential branches of the Wheatstone bridge. A heater was placed in the middle between the thermistors for the indirectly heated type, while for the self-heated type the same thermistors were self-heated by a constant current source. First the thermistor responses vs. the airflow (calibration curves) were measured, and then thermistor responses in time (inertia) to fast airflow changes from the minimum to the maximum. The results obtained could be applied in air conditioning for air guide flow regulation.",
journal = "Recent Developments in Advanced Materials and Processe",
title = "Segmented thermistors printed by NTC nanometric paste and applied in volume air-flow sensors",
pages = "247-252",
volume = "518",
doi = "10.4028/www.scientific.net/MSF.518.247",
url = "https://hdl.handle.net/21.15107/rcub_dais_9556"
}
Aleksić, O. S., Savić, S., Luković, M. D., Radulović, K.,& Lukić, L. S.. (2006). Segmented thermistors printed by NTC nanometric paste and applied in volume air-flow sensors. in Recent Developments in Advanced Materials and Processe, 518, 247-252.
https://doi.org/10.4028/www.scientific.net/MSF.518.247
https://hdl.handle.net/21.15107/rcub_dais_9556
Aleksić OS, Savić S, Luković MD, Radulović K, Lukić LS. Segmented thermistors printed by NTC nanometric paste and applied in volume air-flow sensors. in Recent Developments in Advanced Materials and Processe. 2006;518:247-252.
doi:10.4028/www.scientific.net/MSF.518.247
https://hdl.handle.net/21.15107/rcub_dais_9556 .
Aleksić, Obrad S., Savić, Slavica, Luković, Miloljub D., Radulović, Katarina, Lukić, Lazar S., "Segmented thermistors printed by NTC nanometric paste and applied in volume air-flow sensors" in Recent Developments in Advanced Materials and Processe, 518 (2006):247-252,
https://doi.org/10.4028/www.scientific.net/MSF.518.247 .,
https://hdl.handle.net/21.15107/rcub_dais_9556 .
6
8
6

Photoacoustic investigations of thermal and electronic properties of single crystal Ge doped with Cr

Vasiljević Radović, Dana; Nikolić, Pantelija M.; Radulović, Katarina; Bojičić, Aleksandar I.; Luković, Danijela; Savić, Slavica; Vujatović, Stevan S.; Blagojević, Vladimir D.; Lukić, Lazar S.; Urošević, D.

(E D P Sciences, Les Ulis Cedex A, 2005)

TY  - JOUR
AU  - Vasiljević Radović, Dana
AU  - Nikolić, Pantelija M.
AU  - Radulović, Katarina
AU  - Bojičić, Aleksandar I.
AU  - Luković, Danijela
AU  - Savić, Slavica
AU  - Vujatović, Stevan S.
AU  - Blagojević, Vladimir D.
AU  - Lukić, Lazar S.
AU  - Urošević, D.
PY  - 2005
UR  - https://dais.sanu.ac.rs/123456789/9554
AB  - A high purity single crystal Ge with a (1 1 1) orientation was doped with Cr. A thin film of Cr was evaporated and then diffused into Ge substrate. The photoacoustic PA amplitude and phase spectra were measured and numerically analyzed. The substitution of Cr in Ge produces a compensation effect.
PB  - E D P Sciences, Les Ulis Cedex A
T2  - Journal de physique IV
T1  - Photoacoustic investigations of thermal and electronic properties of single crystal Ge doped with Cr
SP  - 435
EP  - 438
VL  - 125
DO  - 10.1051/jp4:2005125102
UR  - https://hdl.handle.net/21.15107/rcub_dais_9554
ER  - 
@article{
author = "Vasiljević Radović, Dana and Nikolić, Pantelija M. and Radulović, Katarina and Bojičić, Aleksandar I. and Luković, Danijela and Savić, Slavica and Vujatović, Stevan S. and Blagojević, Vladimir D. and Lukić, Lazar S. and Urošević, D.",
year = "2005",
abstract = "A high purity single crystal Ge with a (1 1 1) orientation was doped with Cr. A thin film of Cr was evaporated and then diffused into Ge substrate. The photoacoustic PA amplitude and phase spectra were measured and numerically analyzed. The substitution of Cr in Ge produces a compensation effect.",
publisher = "E D P Sciences, Les Ulis Cedex A",
journal = "Journal de physique IV",
title = "Photoacoustic investigations of thermal and electronic properties of single crystal Ge doped with Cr",
pages = "435-438",
volume = "125",
doi = "10.1051/jp4:2005125102",
url = "https://hdl.handle.net/21.15107/rcub_dais_9554"
}
Vasiljević Radović, D., Nikolić, P. M., Radulović, K., Bojičić, A. I., Luković, D., Savić, S., Vujatović, S. S., Blagojević, V. D., Lukić, L. S.,& Urošević, D.. (2005). Photoacoustic investigations of thermal and electronic properties of single crystal Ge doped with Cr. in Journal de physique IV
E D P Sciences, Les Ulis Cedex A., 125, 435-438.
https://doi.org/10.1051/jp4:2005125102
https://hdl.handle.net/21.15107/rcub_dais_9554
Vasiljević Radović D, Nikolić PM, Radulović K, Bojičić AI, Luković D, Savić S, Vujatović SS, Blagojević VD, Lukić LS, Urošević D. Photoacoustic investigations of thermal and electronic properties of single crystal Ge doped with Cr. in Journal de physique IV. 2005;125:435-438.
doi:10.1051/jp4:2005125102
https://hdl.handle.net/21.15107/rcub_dais_9554 .
Vasiljević Radović, Dana, Nikolić, Pantelija M., Radulović, Katarina, Bojičić, Aleksandar I., Luković, Danijela, Savić, Slavica, Vujatović, Stevan S., Blagojević, Vladimir D., Lukić, Lazar S., Urošević, D., "Photoacoustic investigations of thermal and electronic properties of single crystal Ge doped with Cr" in Journal de physique IV, 125 (2005):435-438,
https://doi.org/10.1051/jp4:2005125102 .,
https://hdl.handle.net/21.15107/rcub_dais_9554 .