Saied, Omar Ali

Link to this page

Authority KeyName Variants
7656fd01-0f35-4d8b-b043-252521322866
  • Saied, Omar Ali (1)
Projects

Author's Bibliography

Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems

Knežević Jugović, Zorica; Jugović, Branimir; Jakovetić, Sonja; Bezbradica, Dejan; Antov, Mirjana; Saied, Omar Ali; Gvozdenović, Milica M.

(Tatranské Matliare : Slovak Society of Chemical Engineering, 2011)

TY  - CONF
AU  - Knežević Jugović, Zorica
AU  - Jugović, Branimir
AU  - Jakovetić, Sonja
AU  - Bezbradica, Dejan
AU  - Antov, Mirjana
AU  - Saied, Omar Ali
AU  - Gvozdenović, Milica M.
PY  - 2011
UR  - https://dais.sanu.ac.rs/123456789/549
AB  - The present study compares the results of two different methods employed for preparation of polyaniline based glucose biosensor with respect to enzyme loading, biosensing efficiency and potential stability. Kinetic analysis of the potentiometric data for two enzyme immobilized electrode systems show that the GOx/PANI electrode is suitable for assaying samples with low analyte concentrations, whereas the GOx/m-ABA/PANI electrode system exhibits a better potential stability. It may therefore be possible to achieve high level of biosensing efficiency by chemical modeling and synthesis combined with careful selection of the immobilization method.
PB  - Tatranské Matliare : Slovak Society of Chemical Engineering
C3  - Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering
T1  - Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems
SP  - 1519
EP  - 1525
UR  - https://hdl.handle.net/21.15107/rcub_dais_549
ER  - 
@conference{
author = "Knežević Jugović, Zorica and Jugović, Branimir and Jakovetić, Sonja and Bezbradica, Dejan and Antov, Mirjana and Saied, Omar Ali and Gvozdenović, Milica M.",
year = "2011",
abstract = "The present study compares the results of two different methods employed for preparation of polyaniline based glucose biosensor with respect to enzyme loading, biosensing efficiency and potential stability. Kinetic analysis of the potentiometric data for two enzyme immobilized electrode systems show that the GOx/PANI electrode is suitable for assaying samples with low analyte concentrations, whereas the GOx/m-ABA/PANI electrode system exhibits a better potential stability. It may therefore be possible to achieve high level of biosensing efficiency by chemical modeling and synthesis combined with careful selection of the immobilization method.",
publisher = "Tatranské Matliare : Slovak Society of Chemical Engineering",
journal = "Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering",
title = "Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems",
pages = "1519-1525",
url = "https://hdl.handle.net/21.15107/rcub_dais_549"
}
Knežević Jugović, Z., Jugović, B., Jakovetić, S., Bezbradica, D., Antov, M., Saied, O. A.,& Gvozdenović, M. M.. (2011). Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems. in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering
Tatranské Matliare : Slovak Society of Chemical Engineering., 1519-1525.
https://hdl.handle.net/21.15107/rcub_dais_549
Knežević Jugović Z, Jugović B, Jakovetić S, Bezbradica D, Antov M, Saied OA, Gvozdenović MM. Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems. in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering. 2011;:1519-1525.
https://hdl.handle.net/21.15107/rcub_dais_549 .
Knežević Jugović, Zorica, Jugović, Branimir, Jakovetić, Sonja, Bezbradica, Dejan, Antov, Mirjana, Saied, Omar Ali, Gvozdenović, Milica M., "Design of a polyaniline based biosensor electrode for glucose: A comparative study of two immobilized systems" in Proceedings of the 38th International Conference of Slovak Society of Chemical Engineering (2011):1519-1525,
https://hdl.handle.net/21.15107/rcub_dais_549 .