Приказ основних података о документу

dc.creatorKrueger, Eddy
dc.creatorPopović Maneski, Lana
dc.creatorNohama, Percy
dc.date.accessioned2018-12-29T09:59:09Z
dc.date.available2019-02-13
dc.date.issued2018
dc.identifier.issn1525-1594
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/abs/10.1111/aor.12973
dc.identifier.urihttps://dais.sanu.ac.rs/123456789/4716
dc.description.abstractA motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord–injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on the rectus femoris, vastus lateralis, and vastus medialis muscles. Data segments were decomposed into 11 frequency bands using a Cauchy wavelet transform. In the initial time interval (non-fatigued muscle), the power peak was concentrated in the 11.31 Hz frequency band. In the final interval (muscle fatigued) this peak shifted to lower frequencies (2 and 6 Hz frequency bands). The decreased frequency was most prominent during the last 4 s of the recordings. It was shown that MMG could be used as a real-time indicator of muscle fatigue during FES-induced isometric contraction of quadriceps; hence, MMG could be used in closed-loop control as a fatigue detector. Subsequent studies for non-isometric contractions could possibly lead to prediction of muscle fatigue before contractile failure during functional use of the muscle.en
dc.languageen
dc.publisherWiley Periodicals, Inc.
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/44008/RS//
dc.rightsembargoedAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourceArtificial Organs
dc.subjectfunctional electrical stimulation
dc.subjectmuscle fatigue
dc.subjectspinal cord injury
dc.subjectwavelet
dc.subjectmechanomyography
dc.titleMechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prosthesesen
dc.typearticleen
dc.rights.licenseBY-NC-ND
dcterms.abstractПоповић‐Манески, Лана; Круегер, Еддy; Нохама, Перцy;
dc.citation.spage208
dc.citation.epage218
dc.citation.volume42
dc.citation.issue2
dc.identifier.wos000424882000015
dc.identifier.doi10.1111/aor.12973
dc.identifier.scopus2-s2.0-85026527007
dc.description.otherThis is the peer-reviewed version of the article: Krueger, E., Popović‐Maneski, L., Nohama, P., 2018. Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses. Artificial Organs 42, 208–218. [https://doi.org/10.1111/aor.12973]
dc.type.versionacceptedVersion
dc.identifier.fulltexthttps://dais.sanu.ac.rs/bitstream/id/14738/Krueger_et_al-2018-Artificial_Organs-postprint.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_dais_4716


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу