Properties of different types of dry electrodes for wearable smart monitoring devices
Samo za registrovane korisnike
2020
Autori
Popović Maneski, LanaIvanović, Marija D.
Atanasoski, Vladimir
Miletić, Marjan
Zdolšek, Sanja
Bojović, Boško
Hadžievski, Ljupčo
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI3...04). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.
Ključne reči:
dry electrodes / ECG / motion artifacts / signal quality / transient impedance / wearable monitorIzvor:
Biomedical Engineering / Biomedizinische Technik, 2020, 65, 4, 405-415Izdavač:
- Walter de Gruyter GmbH
Finansiranje / projekti:
- Razvoj robota kao sredstva za pomoć u prevazilaženju teškoća u razvoju dece (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-44008)
- Fotonika mikro i nano strukturnih materijala (RS-MESTD-Integrated and Interdisciplinary Research (IIR or III)-45010)
Napomena:
- Peer-reviewed manuscript: https://hdl.handle.net/21.15107/rcub_dais_11598
Povezane informacije:
- Druga verzija
https://hdl.handle.net/21.15107/rcub_dais_11598
DOI: 10.1515/bmt-2019-0167
ISSN: 1862-278X; 0013-5585
WoS: 000560600600003
Scopus: 2-s2.0-85083206490
Institucija/grupa
Институт техничких наука САНУ / Institute of Technical Sciences of SASATY - JOUR AU - Popović Maneski, Lana AU - Ivanović, Marija D. AU - Atanasoski, Vladimir AU - Miletić, Marjan AU - Zdolšek, Sanja AU - Bojović, Boško AU - Hadžievski, Ljupčo PY - 2020 UR - https://dais.sanu.ac.rs/123456789/10028 AB - Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs. PB - Walter de Gruyter GmbH T2 - Biomedical Engineering / Biomedizinische Technik T1 - Properties of different types of dry electrodes for wearable smart monitoring devices SP - 405 EP - 415 VL - 65 IS - 4 DO - 10.1515/bmt-2019-0167 UR - https://hdl.handle.net/21.15107/rcub_dais_10028 ER -
@article{ author = "Popović Maneski, Lana and Ivanović, Marija D. and Atanasoski, Vladimir and Miletić, Marjan and Zdolšek, Sanja and Bojović, Boško and Hadžievski, Ljupčo", year = "2020", abstract = "Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.", publisher = "Walter de Gruyter GmbH", journal = "Biomedical Engineering / Biomedizinische Technik", title = "Properties of different types of dry electrodes for wearable smart monitoring devices", pages = "405-415", volume = "65", number = "4", doi = "10.1515/bmt-2019-0167", url = "https://hdl.handle.net/21.15107/rcub_dais_10028" }
Popović Maneski, L., Ivanović, M. D., Atanasoski, V., Miletić, M., Zdolšek, S., Bojović, B.,& Hadžievski, L.. (2020). Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik Walter de Gruyter GmbH., 65(4), 405-415. https://doi.org/10.1515/bmt-2019-0167 https://hdl.handle.net/21.15107/rcub_dais_10028
Popović Maneski L, Ivanović MD, Atanasoski V, Miletić M, Zdolšek S, Bojović B, Hadžievski L. Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik. 2020;65(4):405-415. doi:10.1515/bmt-2019-0167 https://hdl.handle.net/21.15107/rcub_dais_10028 .
Popović Maneski, Lana, Ivanović, Marija D., Atanasoski, Vladimir, Miletić, Marjan, Zdolšek, Sanja, Bojović, Boško, Hadžievski, Ljupčo, "Properties of different types of dry electrodes for wearable smart monitoring devices" in Biomedical Engineering / Biomedizinische Technik, 65, no. 4 (2020):405-415, https://doi.org/10.1515/bmt-2019-0167 ., https://hdl.handle.net/21.15107/rcub_dais_10028 .