Neuromuscular fatigue detection by mechanomyography in people with complete spinal cord injury

Krueger, Eddy; Popović-Maneski, Lana; Neto, Guilherme Nunes Nogueira; Mendonça Scheeren, Eduardo; Fiusa, Jessika Mehret; Nohama, Percy

(Springer, 2020)

TY  - JOUR
AU  - Krueger, Eddy
AU  - Popović-Maneski, Lana
AU  - Neto, Guilherme Nunes Nogueira
AU  - Mendonça Scheeren, Eduardo
AU  - Fiusa, Jessika Mehret
AU  - Nohama, Percy
PY  - 2020
UR  - https://doi.org/10.1007/s42600-020-00061-z
UR  - https://dais.sanu.ac.rs/123456789/9817
AB  - Functional electrical stimulation (FES) is a method of activating paralyzed muscles. During FES application, fast muscle fatigue can occur (the inability of stimulated muscles to generate force). Therefore, it is beneficial to estimate the muscle fatigue for FES closed-loop control for walking to prevent unexpected muscle collapse and adapt the FES strategy in real time. Mechanomyography (MMG) is a noninvasive technique for registering myofiber vibrations, representing an ideal candidate for the provision of feedback. The hypothesis was that MMG signals could effectively detect muscle fatigue and, thus, provide feedback.
PB  - Springer
T2  - Research on Biomedical Engineering
T1  - Neuromuscular fatigue detection by mechanomyography in people with complete spinal cord injury
SP  - 203
EP  - 212
VL  - 36
IS  - 3
DO  - 10.1007/s42600-020-00061-z
UR  - https://hdl.handle.net/21.15107/rcub_dais_9817
ER  - 
@article{
author = "Krueger, Eddy and Popović-Maneski, Lana and Neto, Guilherme Nunes Nogueira and Mendonça Scheeren, Eduardo and Fiusa, Jessika Mehret and Nohama, Percy",
year = "2020",
abstract = "Functional electrical stimulation (FES) is a method of activating paralyzed muscles. During FES application, fast muscle fatigue can occur (the inability of stimulated muscles to generate force). Therefore, it is beneficial to estimate the muscle fatigue for FES closed-loop control for walking to prevent unexpected muscle collapse and adapt the FES strategy in real time. Mechanomyography (MMG) is a noninvasive technique for registering myofiber vibrations, representing an ideal candidate for the provision of feedback. The hypothesis was that MMG signals could effectively detect muscle fatigue and, thus, provide feedback.",
publisher = "Springer",
journal = "Research on Biomedical Engineering",
title = "Neuromuscular fatigue detection by mechanomyography in people with complete spinal cord injury",
pages = "203-212",
volume = "36",
number = "3",
doi = "10.1007/s42600-020-00061-z",
url = "https://hdl.handle.net/21.15107/rcub_dais_9817"
}
Krueger, E., Popović-Maneski, L., Neto, G. N. N., Mendonça Scheeren, E., Fiusa, J. M.,& Nohama, P.. (2020). Neuromuscular fatigue detection by mechanomyography in people with complete spinal cord injury. in Research on Biomedical Engineering
Springer., 36(3), 203-212.
https://doi.org/10.1007/s42600-020-00061-z
https://hdl.handle.net/21.15107/rcub_dais_9817
Krueger E, Popović-Maneski L, Neto GNN, Mendonça Scheeren E, Fiusa JM, Nohama P. Neuromuscular fatigue detection by mechanomyography in people with complete spinal cord injury. in Research on Biomedical Engineering. 2020;36(3):203-212.
doi:10.1007/s42600-020-00061-z
https://hdl.handle.net/21.15107/rcub_dais_9817 .
Krueger, Eddy, Popović-Maneski, Lana, Neto, Guilherme Nunes Nogueira, Mendonça Scheeren, Eduardo, Fiusa, Jessika Mehret, Nohama, Percy, "Neuromuscular fatigue detection by mechanomyography in people with complete spinal cord injury" in Research on Biomedical Engineering, 36, no. 3 (2020):203-212,
https://doi.org/10.1007/s42600-020-00061-z .,
https://hdl.handle.net/21.15107/rcub_dais_9817 .
3
3

Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses

Krueger, Eddy; Popović Maneski, Lana; Nohama, Percy

(Wiley Periodicals, Inc., 2018)

TY  - JOUR
AU  - Krueger, Eddy
AU  - Popović Maneski, Lana
AU  - Nohama, Percy
PY  - 2018
UR  - https://onlinelibrary.wiley.com/doi/abs/10.1111/aor.12973
UR  - https://dais.sanu.ac.rs/123456789/4716
AB  - A motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord–injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on the rectus femoris, vastus lateralis, and vastus medialis muscles. Data segments were decomposed into 11 frequency bands using a Cauchy wavelet transform. In the initial time interval (non-fatigued muscle), the power peak was concentrated in the 11.31 Hz frequency band. In the final interval (muscle fatigued) this peak shifted to lower frequencies (2 and 6 Hz frequency bands). The decreased frequency was most prominent during the last 4 s of the recordings. It was shown that MMG could be used as a real-time indicator of muscle fatigue during FES-induced isometric contraction of quadriceps; hence, MMG could be used in closed-loop control as a fatigue detector. Subsequent studies for non-isometric contractions could possibly lead to prediction of muscle fatigue before contractile failure during functional use of the muscle.
PB  - Wiley Periodicals, Inc.
T2  - Artificial Organs
T1  - Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses
SP  - 208
EP  - 218
VL  - 42
IS  - 2
DO  - 10.1111/aor.12973
UR  - https://hdl.handle.net/21.15107/rcub_dais_4716
ER  - 
@article{
author = "Krueger, Eddy and Popović Maneski, Lana and Nohama, Percy",
year = "2018",
abstract = "A motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord–injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on the rectus femoris, vastus lateralis, and vastus medialis muscles. Data segments were decomposed into 11 frequency bands using a Cauchy wavelet transform. In the initial time interval (non-fatigued muscle), the power peak was concentrated in the 11.31 Hz frequency band. In the final interval (muscle fatigued) this peak shifted to lower frequencies (2 and 6 Hz frequency bands). The decreased frequency was most prominent during the last 4 s of the recordings. It was shown that MMG could be used as a real-time indicator of muscle fatigue during FES-induced isometric contraction of quadriceps; hence, MMG could be used in closed-loop control as a fatigue detector. Subsequent studies for non-isometric contractions could possibly lead to prediction of muscle fatigue before contractile failure during functional use of the muscle.",
publisher = "Wiley Periodicals, Inc.",
journal = "Artificial Organs",
title = "Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses",
pages = "208-218",
volume = "42",
number = "2",
doi = "10.1111/aor.12973",
url = "https://hdl.handle.net/21.15107/rcub_dais_4716"
}
Krueger, E., Popović Maneski, L.,& Nohama, P.. (2018). Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses. in Artificial Organs
Wiley Periodicals, Inc.., 42(2), 208-218.
https://doi.org/10.1111/aor.12973
https://hdl.handle.net/21.15107/rcub_dais_4716
Krueger E, Popović Maneski L, Nohama P. Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses. in Artificial Organs. 2018;42(2):208-218.
doi:10.1111/aor.12973
https://hdl.handle.net/21.15107/rcub_dais_4716 .
Krueger, Eddy, Popović Maneski, Lana, Nohama, Percy, "Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses" in Artificial Organs, 42, no. 2 (2018):208-218,
https://doi.org/10.1111/aor.12973 .,
https://hdl.handle.net/21.15107/rcub_dais_4716 .
8
6
7

Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses

Krueger, Eddy; Popović Maneski, Lana; Nohama, Percy

(Wiley Periodicals, Inc., 2018)

TY  - JOUR
AU  - Krueger, Eddy
AU  - Popović Maneski, Lana
AU  - Nohama, Percy
PY  - 2018
UR  - https://onlinelibrary.wiley.com/doi/abs/10.1111/aor.12973
UR  - https://dais.sanu.ac.rs/123456789/4593
AB  - A motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord–injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on the rectus femoris, vastus lateralis, and vastus medialis muscles. Data segments were decomposed into 11 frequency bands using a Cauchy wavelet transform. In the initial time interval (non-fatigued muscle), the power peak was concentrated in the 11.31 Hz frequency band. In the final interval (muscle fatigued) this peak shifted to lower frequencies (2 and 6 Hz frequency bands). The decreased frequency was most prominent during the last 4 s of the recordings. It was shown that MMG could be used as a real-time indicator of muscle fatigue during FES-induced isometric contraction of quadriceps; hence, MMG could be used in closed-loop control as a fatigue detector. Subsequent studies for non-isometric contractions could possibly lead to prediction of muscle fatigue before contractile failure during functional use of the muscle.
PB  - Wiley Periodicals, Inc.
T2  - Artificial Organs
T1  - Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses
SP  - 208
EP  - 218
VL  - 42
IS  - 2
DO  - 10.1111/aor.12973
UR  - https://hdl.handle.net/21.15107/rcub_dais_4593
ER  - 
@article{
author = "Krueger, Eddy and Popović Maneski, Lana and Nohama, Percy",
year = "2018",
abstract = "A motor neural prosthesis based on surface functional electrical stimulation (sFES) can restore functional movement (e.g., standing, walking) in patients with a spinal cord injury (SCI). sFES generates muscle contractions in antigravity muscles and allows balance-assisted standing. This induced standing has several benefits, such as improved cardiovascular function, decreased incidence of urinary infections, reduced joint contractures, and muscle atrophy. The duration of sFES assisted standing is limited due to the quick onset of muscle fatigue. Currently, there is no method available to reliably estimate real-time muscle fatigue during sFES. Simply monitoring the M-wave changes is not suitable due to the high signal disturbances that arise during multi-channel electrical stimulation. Mechanomyography (MMG) is immune to electrical stimulation artifacts and can be used to detect subtle vibrations on the surface of the skin related to activation of the underlying muscle's motor units (MU). The aim of this study was to develop a method for detecting muscle fatigue brought on by sFES. The method was tested in three different heads of the quadriceps muscle in SCI patients during electrically elicited quasi-isometric contraction. Six spinal cord–injured male volunteers, with no voluntary control of the quadriceps muscle participated in the study. Electrical bursts of voltage-controlled monophasic square pulses at frequencies of 1 kHz (50% duty cycle) at 50 Hz (15% duty cycle) were used to generate thigh muscle contractions that controlled the knee joint in the sagittal plane. The pulse amplitudes were set to position the knee joint at a 5° angle from the horizontal plane and when the knee angle dropped to 20° (e.g., the quadriceps were unable to hold the lower leg in the desired position), the test was terminated. Two data segments lasting 10 s each, at the beginning and end of each test, were analyzed. The muscle contraction was assessed by MMG sensors positioned on the rectus femoris, vastus lateralis, and vastus medialis muscles. Data segments were decomposed into 11 frequency bands using a Cauchy wavelet transform. In the initial time interval (non-fatigued muscle), the power peak was concentrated in the 11.31 Hz frequency band. In the final interval (muscle fatigued) this peak shifted to lower frequencies (2 and 6 Hz frequency bands). The decreased frequency was most prominent during the last 4 s of the recordings. It was shown that MMG could be used as a real-time indicator of muscle fatigue during FES-induced isometric contraction of quadriceps; hence, MMG could be used in closed-loop control as a fatigue detector. Subsequent studies for non-isometric contractions could possibly lead to prediction of muscle fatigue before contractile failure during functional use of the muscle.",
publisher = "Wiley Periodicals, Inc.",
journal = "Artificial Organs",
title = "Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses",
pages = "208-218",
volume = "42",
number = "2",
doi = "10.1111/aor.12973",
url = "https://hdl.handle.net/21.15107/rcub_dais_4593"
}
Krueger, E., Popović Maneski, L.,& Nohama, P.. (2018). Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses. in Artificial Organs
Wiley Periodicals, Inc.., 42(2), 208-218.
https://doi.org/10.1111/aor.12973
https://hdl.handle.net/21.15107/rcub_dais_4593
Krueger E, Popović Maneski L, Nohama P. Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses. in Artificial Organs. 2018;42(2):208-218.
doi:10.1111/aor.12973
https://hdl.handle.net/21.15107/rcub_dais_4593 .
Krueger, Eddy, Popović Maneski, Lana, Nohama, Percy, "Mechanomyography-Based Wearable Monitor of Quasi-Isometric Muscle Fatigue for Motor Neural Prostheses" in Artificial Organs, 42, no. 2 (2018):208-218,
https://doi.org/10.1111/aor.12973 .,
https://hdl.handle.net/21.15107/rcub_dais_4593 .
8
6
7