Bojović, Boško

Link to this page

Authority KeyName Variants
bojovic-b-123456
  • Bojović, Boško (3)
Projects

Author's Bibliography

Properties of different types of dry electrodes for wearable smart monitoring devices

Popović Maneski, Lana; Ivanović, Marija D.; Atanasoski, Vladimir; Miletić, Marjan; Zdolšek, Sanja; Bojović, Boško; Hadžievski, Ljupčo

(Walter de Gruyter GmbH, 2020)

TY  - JOUR
AU  - Popović Maneski, Lana
AU  - Ivanović, Marija D.
AU  - Atanasoski, Vladimir
AU  - Miletić, Marjan
AU  - Zdolšek, Sanja
AU  - Bojović, Boško
AU  - Hadžievski, Ljupčo
PY  - 2020
UR  - https://dais.sanu.ac.rs/123456789/11598
AB  - Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.
PB  - Walter de Gruyter GmbH
T2  - Biomedical Engineering / Biomedizinische Technik
T1  - Properties of different types of dry electrodes for wearable smart monitoring devices
SP  - 405
EP  - 415
VL  - 65
IS  - 4
DO  - 10.1515/bmt-2019-0167
UR  - https://hdl.handle.net/21.15107/rcub_dais_11598
ER  - 
@article{
author = "Popović Maneski, Lana and Ivanović, Marija D. and Atanasoski, Vladimir and Miletić, Marjan and Zdolšek, Sanja and Bojović, Boško and Hadžievski, Ljupčo",
year = "2020",
abstract = "Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.",
publisher = "Walter de Gruyter GmbH",
journal = "Biomedical Engineering / Biomedizinische Technik",
title = "Properties of different types of dry electrodes for wearable smart monitoring devices",
pages = "405-415",
volume = "65",
number = "4",
doi = "10.1515/bmt-2019-0167",
url = "https://hdl.handle.net/21.15107/rcub_dais_11598"
}
Popović Maneski, L., Ivanović, M. D., Atanasoski, V., Miletić, M., Zdolšek, S., Bojović, B.,& Hadžievski, L.. (2020). Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik
Walter de Gruyter GmbH., 65(4), 405-415.
https://doi.org/10.1515/bmt-2019-0167
https://hdl.handle.net/21.15107/rcub_dais_11598
Popović Maneski L, Ivanović MD, Atanasoski V, Miletić M, Zdolšek S, Bojović B, Hadžievski L. Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik. 2020;65(4):405-415.
doi:10.1515/bmt-2019-0167
https://hdl.handle.net/21.15107/rcub_dais_11598 .
Popović Maneski, Lana, Ivanović, Marija D., Atanasoski, Vladimir, Miletić, Marjan, Zdolšek, Sanja, Bojović, Boško, Hadžievski, Ljupčo, "Properties of different types of dry electrodes for wearable smart monitoring devices" in Biomedical Engineering / Biomedizinische Technik, 65, no. 4 (2020):405-415,
https://doi.org/10.1515/bmt-2019-0167 .,
https://hdl.handle.net/21.15107/rcub_dais_11598 .
8
8

Properties of different types of dry electrodes for wearable smart monitoring devices

Popović Maneski, Lana; Ivanović, Marija D.; Atanasoski, Vladimir; Miletić, Marjan; Zdolšek, Sanja; Bojović, Boško; Hadžievski, Ljupčo

(Walter de Gruyter GmbH, 2020)

TY  - JOUR
AU  - Popović Maneski, Lana
AU  - Ivanović, Marija D.
AU  - Atanasoski, Vladimir
AU  - Miletić, Marjan
AU  - Zdolšek, Sanja
AU  - Bojović, Boško
AU  - Hadžievski, Ljupčo
PY  - 2020
UR  - https://dais.sanu.ac.rs/123456789/10028
AB  - Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.
PB  - Walter de Gruyter GmbH
T2  - Biomedical Engineering / Biomedizinische Technik
T1  - Properties of different types of dry electrodes for wearable smart monitoring devices
SP  - 405
EP  - 415
VL  - 65
IS  - 4
DO  - 10.1515/bmt-2019-0167
UR  - https://hdl.handle.net/21.15107/rcub_dais_10028
ER  - 
@article{
author = "Popović Maneski, Lana and Ivanović, Marija D. and Atanasoski, Vladimir and Miletić, Marjan and Zdolšek, Sanja and Bojović, Boško and Hadžievski, Ljupčo",
year = "2020",
abstract = "Wearable smart monitors (WSMs) applied for the estimation of electrophysiological signals are of utmost interest for a non-stressed life. WSM which records heart muscle activities could signalize timely a life-threatening event. The heart muscle activities are typically recorded across the heart at the surface of the body; hence, a WSM monitor requires high-quality surface electrodes. The electrodes used in the clinical settings [i.e. silver/silver chloride (Ag/AgCl) with the gel] are not practical for the daily out of clinic usage. A practical WSM requires the application of a dry electrode with stable and reproducible electrical characteristics. We compared the characteristics of six types of dry electrodes and one gelled electrode during short-term recordings sessions (≈30 s) in real-life conditions: Orbital, monolithic polymer plated with Ag/AgCl, and five rectangular shaped 10 × 6 × 2 mm electrodes (Orbital, Ag electrode, Ag/AgCl electrode, gold electrode and stainless-steel AISI304). The results of a well-controlled analysis which considered motion artifacts, line noise and junction potentials suggest that among the dry electrodes Ag/AgCl performs the best. The Ag/AgCl electrode is in average three times better compared with the stainless-steel electrode often used in WSMs.",
publisher = "Walter de Gruyter GmbH",
journal = "Biomedical Engineering / Biomedizinische Technik",
title = "Properties of different types of dry electrodes for wearable smart monitoring devices",
pages = "405-415",
volume = "65",
number = "4",
doi = "10.1515/bmt-2019-0167",
url = "https://hdl.handle.net/21.15107/rcub_dais_10028"
}
Popović Maneski, L., Ivanović, M. D., Atanasoski, V., Miletić, M., Zdolšek, S., Bojović, B.,& Hadžievski, L.. (2020). Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik
Walter de Gruyter GmbH., 65(4), 405-415.
https://doi.org/10.1515/bmt-2019-0167
https://hdl.handle.net/21.15107/rcub_dais_10028
Popović Maneski L, Ivanović MD, Atanasoski V, Miletić M, Zdolšek S, Bojović B, Hadžievski L. Properties of different types of dry electrodes for wearable smart monitoring devices. in Biomedical Engineering / Biomedizinische Technik. 2020;65(4):405-415.
doi:10.1515/bmt-2019-0167
https://hdl.handle.net/21.15107/rcub_dais_10028 .
Popović Maneski, Lana, Ivanović, Marija D., Atanasoski, Vladimir, Miletić, Marjan, Zdolšek, Sanja, Bojović, Boško, Hadžievski, Ljupčo, "Properties of different types of dry electrodes for wearable smart monitoring devices" in Biomedical Engineering / Biomedizinische Technik, 65, no. 4 (2020):405-415,
https://doi.org/10.1515/bmt-2019-0167 .,
https://hdl.handle.net/21.15107/rcub_dais_10028 .
8
8

Application of multiparametric cardiac measurement system in ejection fraction calculation

Miletić, Marjan; Ivanović, Marija D.; Popović Maneski, Lana; Bojović, Boško

(Belgrade : Institute of Physics Belgrade, 2017)

TY  - CONF
AU  - Miletić, Marjan
AU  - Ivanović, Marija D.
AU  - Popović Maneski, Lana
AU  - Bojović, Boško
PY  - 2017
UR  - https://dais.sanu.ac.rs/123456789/15422
AB  - Ejection fraction (EF) is the most used parameter for characterisation of Heart Failure (HF) condition. EF is commonly calculated using echocardiography, which is an expensive non–invasive method and not used in primary healthcare. Systolic time intervals (STI) represent a non-invasive and inexpensive method for determination of EF[1, 2]. Heart failure (HF) is the single most expensive diagnosis in medicine. 2–3% of adult population in developed countries have HF diagnosis. It is not detectable by ECG test and it is commonly detected in a late stage, when the process is irreversible [2-5]. In this paper, a multiparametric cardiac measurement system for determination of STI is presented. Measurement system consists of sensors for simultaneous acquisition of electrocardiographic (ECG), phonocardiographic (PCG), photopletysmographic (PPG) and cardiovascular (CV) pulsation signals. CV pulsation signals are measured by long period grating (LPG) fiber-optic sensors[6]. Two non-invasive methods for measuring systolic time intervals (STI) were applied on a set of 6 healthy volunteers, based on ECG, PCG and CV pulsation signals. CV pulsation signals were measured on carotide arthery with PPG and LPG sensors. In the first method, EF was calculated from the obtained STI signals, using CV carotide pulsations measured with the PPG sensor, giving EF values in the range from 0.60 to 0.68, with maximal standard deviation of 0.05. In the second method, EF was obtained using CV carotide pulsations measured with LPG sensor, giving EF values in the range from 0.60 to 0.66, with maximal standard deviation 0.06. Calculated values of EF with both methods were in the 0.55 to 0.75 range which corresponds to normal EF range in healthy individuals.
PB  - Belgrade : Institute of Physics Belgrade
C3  - Abstracts of Tutorial, Keynote, Invited Lectures, Progress Reports and Contributed Papers of the Sixth International School and Conference on Photonics PHOTONICA2017, 28 August – 1 September 2017, Belgrade Serbia
T1  - Application of multiparametric cardiac measurement system in ejection fraction calculation
SP  - 112
EP  - 112
UR  - https://hdl.handle.net/21.15107/rcub_dais_15422
ER  - 
@conference{
author = "Miletić, Marjan and Ivanović, Marija D. and Popović Maneski, Lana and Bojović, Boško",
year = "2017",
abstract = "Ejection fraction (EF) is the most used parameter for characterisation of Heart Failure (HF) condition. EF is commonly calculated using echocardiography, which is an expensive non–invasive method and not used in primary healthcare. Systolic time intervals (STI) represent a non-invasive and inexpensive method for determination of EF[1, 2]. Heart failure (HF) is the single most expensive diagnosis in medicine. 2–3% of adult population in developed countries have HF diagnosis. It is not detectable by ECG test and it is commonly detected in a late stage, when the process is irreversible [2-5]. In this paper, a multiparametric cardiac measurement system for determination of STI is presented. Measurement system consists of sensors for simultaneous acquisition of electrocardiographic (ECG), phonocardiographic (PCG), photopletysmographic (PPG) and cardiovascular (CV) pulsation signals. CV pulsation signals are measured by long period grating (LPG) fiber-optic sensors[6]. Two non-invasive methods for measuring systolic time intervals (STI) were applied on a set of 6 healthy volunteers, based on ECG, PCG and CV pulsation signals. CV pulsation signals were measured on carotide arthery with PPG and LPG sensors. In the first method, EF was calculated from the obtained STI signals, using CV carotide pulsations measured with the PPG sensor, giving EF values in the range from 0.60 to 0.68, with maximal standard deviation of 0.05. In the second method, EF was obtained using CV carotide pulsations measured with LPG sensor, giving EF values in the range from 0.60 to 0.66, with maximal standard deviation 0.06. Calculated values of EF with both methods were in the 0.55 to 0.75 range which corresponds to normal EF range in healthy individuals.",
publisher = "Belgrade : Institute of Physics Belgrade",
journal = "Abstracts of Tutorial, Keynote, Invited Lectures, Progress Reports and Contributed Papers of the Sixth International School and Conference on Photonics PHOTONICA2017, 28 August – 1 September 2017, Belgrade Serbia",
title = "Application of multiparametric cardiac measurement system in ejection fraction calculation",
pages = "112-112",
url = "https://hdl.handle.net/21.15107/rcub_dais_15422"
}
Miletić, M., Ivanović, M. D., Popović Maneski, L.,& Bojović, B.. (2017). Application of multiparametric cardiac measurement system in ejection fraction calculation. in Abstracts of Tutorial, Keynote, Invited Lectures, Progress Reports and Contributed Papers of the Sixth International School and Conference on Photonics PHOTONICA2017, 28 August – 1 September 2017, Belgrade Serbia
Belgrade : Institute of Physics Belgrade., 112-112.
https://hdl.handle.net/21.15107/rcub_dais_15422
Miletić M, Ivanović MD, Popović Maneski L, Bojović B. Application of multiparametric cardiac measurement system in ejection fraction calculation. in Abstracts of Tutorial, Keynote, Invited Lectures, Progress Reports and Contributed Papers of the Sixth International School and Conference on Photonics PHOTONICA2017, 28 August – 1 September 2017, Belgrade Serbia. 2017;:112-112.
https://hdl.handle.net/21.15107/rcub_dais_15422 .
Miletić, Marjan, Ivanović, Marija D., Popović Maneski, Lana, Bojović, Boško, "Application of multiparametric cardiac measurement system in ejection fraction calculation" in Abstracts of Tutorial, Keynote, Invited Lectures, Progress Reports and Contributed Papers of the Sixth International School and Conference on Photonics PHOTONICA2017, 28 August – 1 September 2017, Belgrade Serbia (2017):112-112,
https://hdl.handle.net/21.15107/rcub_dais_15422 .